Journal: :Physics in medicine and biology 2011
B Schaeken R Cuypers J Goossens D Van den Weyngaert D Verellen

An experimental determination of the energy correction factor for alanine/paraffin pellets in the 192Ir spectrum at varying distances from the source is presented. Alanine dosimeters were irradiated in water under full scatter conditions with a high dose rate (HDR) 192Ir source (Flexisource), using a dedicated holder. Up to six line sources (catheters) fit in a regular pattern at fixed radial d...

Journal: :iranian journal of radiation research 0
n. babaei bidmeshki department of energy engineering, sharif university of technology, p.o. box 1485893169, tehran, iran m. sohrabpour department of energy engineering, sharif university of technology, p.o. box 1485893169, tehran, iran s.r. mahdavi department of medical physics, faculty of medicine, tehran university of medical sciences p.o. box 1449614525, tehran, iran

background: the purpose of this project was to derive the brachytherapy dosimetric functions described by american association of physicists in medicine (aapm) tg-43 u1 based on high dose rate 192i sources. materials and methods: the method utilized included both simulation of the designed polymethyl methacrylate (pmma) phantom using the monte carlo of mcnp4c and benchmarking of the simulation ...

2015
Yoshinori Miyahara Hajime Kitagaki Tomonori Nishimura Kanae Itakura Shinobu Takahashi Masaki Yokokawa Nobue Uchida Taisuke Inomata

The routine quality assurance (QA) procedure for a high-dose-rate (HDR) 192Ir radioactive source is an important task to provide appropriate brachytherapy. Traditionally, it has been difficult to obtain good quality images using the 192Ir source due to irradiation from the high-energy gamma rays. However, a direct-conversion flat-panel detector (d-FPD) has made it possible to confirm the locali...

2018
Irina Fotina Kyveli Zourari Vasileios Lahanas Evaggelos Pantelis Panagiotis Papagiannis

Purpose To perform a comparative study of heterogeneities and finite patient dimension effects in 60Co and 192Ir high-dose-rate (HDR) brachytherapy. Material and methods Clinically equivalent plans were prepared for 19 cases (8 breast, 5 esophagus, 6 gynecologic) using the Ir2.A85-2 and the Co0.A86 HDR sources, with a TG-43 based treatment planning system (TPS). Phase space files were obtaine...

Journal: :Circulation 2002
Mark A Grise Vincent Massullo Shirish Jani Jeffrey J Popma Robert J Russo Richard A Schatz Erminia M Guarneri Stephen Steuterman David A Cloutier Martin B Leon Prabhakar Tripuraneni Paul S Teirstein

BACKGROUND Several clinical trials indicate that intracoronary radiation is safe and effective for treatment of restenotic coronary arteries. We previously reported 6-month and 3-year clinical and angiographic follow-up demonstrating significant decreases in target lesion revascularization (TLR) and angiographic restenosis after gamma radiation of restenotic lesions. The objective of this study...

Journal: :Circulation 1999
P S Teirstein V Massullo S Jani R J Russo D A Cloutier R A Schatz E M Guarneri S Steuterman K Sirkin S Norman P Tripuraneni

BACKGROUND Although early trials indicate the treatment of restenosis with radiation therapy is safe and effective, the long-term impact of this new technology has been questioned. The possibility of late untoward consequences, such as aneurysm formation, perforation, and accelerated vascular disease, is of significant concern. Furthermore, it is not known whether the beneficial effects of radi...

2015
Delaram Pakravan Mahdi Ghorbani Ali Soleimani Meigooni

PURPOSE Recently a number of hypothetical sources have been proposed and evaluated for use in brachytherapy. In the present study, a hypothetical (101)Rh source with mean photon energy of 121.5 keV and half-life of 3.3 years, has been evaluated as an alternative to the existing high-dose-rate (HDR) sources. Dosimetric characteristics of this source model have been determined following the recom...

2014
Carlos Eduardo deAlmeida Ricardo Ochoa Marilene Coelho de Lima Mariano Gazineu David Evandro Jesus Pires José Guilherme Peixoto Camila Salata Mario Antônio Bernal

High dose rate brachytherapy (HDR) using 192Ir sources is well accepted as an important treatment option and thus requires an accurate dosimetry standard. However, a dosimetry standard for the direct measurement of the absolute dose to water for this particular source type is currently not available. An improved standard for the absorbed dose to water based on Fricke dosimetry of HDR 192Ir brac...

2017
Subhalaxmi Mishra T. Palani Selvam

PURPOSE To investigate beam quality correction, KQQ0 (r) and phantom scatter correction, Kphan (r) for lithium formate dosimeter as a function of distance r along the transverse axis of the high-energy brachytherapy sources 60Co, 137Cs, 192Ir and 169Yb using the Monte Carlo-based EGSnrc code system. MATERIALS AND METHODS The brachytherapy sources investigated in this study are BEBIG High Dose...