نتایج جستجو برای: swimming pool heat exchanger

تعداد نتایج: 269304  

2017
Hassan Hajabdollahi

Economic optimization of shell and tube heat exchanger (STHE) is presented in this paper. To increase the rate of heat transfer, copper oxide (CuO) nanoparticle is added into the tube side fluid and their optimum results are compared with the case of without additive nanoparticle. Total annual cost (TAC) is selected as fitness function and nine decision variables related to the heat exchanger p...

2009
Varun Singh Reinhard Radermacher Jungho Kim

Title of Document: DEVELOPMENT OF AN ADVANCED HEAT EXCHANGER MODEL FOR STEADY STATE AND FROSTING CONDITIONS Varun Singh Doctor of Philosophy, 2009 Directed By: Reinhard Radermacher, Professor Department of Mechanical Engineering Air-to-refrigerant fin-and-tube heat exchangers are a key component in the heating, air conditioning and refrigeration industry. Considering their dominance, the indust...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2004
mahmood reza hojjati mohammad reza omidkhah mohammad hassan panjeh shahi

this paper presents a simple methodology for cost estimation of a near optimal heat exchanger network, which comprises mixed materials of construction. intraditional pinch technology and mathematical programming it is usually assumed that all heat exchangers in a network obey a single cost model. this implies that all heat exchangers  in a network are of the same type and use the same materials...

Journal: :iranian journal of hydrogen and fuel cell 0
ali saberimoghaddam malek ashtar university of technology mohammad mahdi bahri rasht abadi department of chemistry and chemical engineering, faculty of chemical engineering, malek ashtar university of technology (mut), lavizan 158751774, tehran, iran

joule-thomson cooling systems are used in refrigeration processes such as cryogenic gas liquefaction. although extensive studies have been carried out by researchers, most of them include cryogenic heat exchangers and their associated fields. in the current study, an attempt was made to indicate the effect of using inappropriate operational conditions in a cryogenic joule-thomson cooling system...

Journal: :Annali dell'Istituto superiore di sanita 2012
Cristina M Villanueva Laia Font-Ribera

This article is focused on the epidemiological evidence on the health impacts related to disinfection by-products (DBPs) in swimming pools, which is a chemical hazard generated as an undesired consequence to reduce the microbial pathogens. Specific DBPs are carcinogenic, fetotoxic and/or irritant to the airways according to experimental studies. Epidemiological evidence shows that swimming ...

2013
Ian Bell Eckhard A. Groll Ian H. Bell

In this study, the air-side pressure drop and heat transfer performance of plate-fin and microchannel coils were tested under clean and fouled conditions. The heat exchangers were tested with two different types of dust, ASHRAE dust and Arizona Road Test Dust. The ASHRAE dust was found to have a very significant impact on the pressure drop of the microchannel heat exchanger, increasing the air-...

2014
Ian H. Bell Eckhard A. Groll

In this study, the air-side pressure drop and heat transfer performance of plate-fin and microchannel coils were tested under clean and fouled conditions. The heat exchangers were tested with two different types of dust, ASHRAE Standard Dust and Arizona Road Test Dust. The ASHRAE dust was found to have a very significant impact on the pressure drop of the microchannel heat exchanger, increasing...

Journal: :international journal of geo science and environmental planning 0
seyed amirodin sadrnejhad prof, civil engineering dept., k.n.toosi university of technology, teheran, iran mir sina mousavi aghdam msc,khak energy pars., geotechnical consultant co, teheran, iran mahsa memarianfard phd civil engineering dept., k.n.toosi university of technology, teheran, iran zahra sharif tehrani msc student.faculty of art and architecture. kashan university, kashan, iran

an investigation on the thermal performance of the soil as geothermal heat energy storage medium has been conducted. the thermal characteristics of the soil storage and the heat transfer from a heat exchanger in the soil, surrounding and bottom surface will be discussed. this investigation forms a contribution to a project to realize such storage to be charged from a solar heating system. this ...

2014
Yunho Hwang Sahil Popli Reinhard Radermacher Sahil POPLI Yunho HWANG Reinhard RADERMACHER

An experimental study has been conducted to evaluate the performance of a compact round-tube louver-fin condenser, each with frontal areas of 0.25 m in both dry and wet conditions. Deluge water cooling is achieved by incorporating a perforated bottom plate-type water distributor on top of the round tube heat exchanger. Water is used as a refrigerant, and enters the heat exchanger tubes at 35°C ...

Journal: :Gaceta sanitaria 2013
Álvaro Fernández-Luna Pablo Burillo José Luis Felipe Leonor Gallardo Francisco Manuel Tamaral

OBJECTIVE To describe chlorine levels in the air of indoor swimming pools in Castilla-La Mancha (Spain) and relate them to other chemical parameters in the installation and to the health problems perceived by swimming pool workers. METHODS We analyzed 21 pools with chlorine as chemical treatment in Castilla-La Mancha. The iodometry method was applied to measure chlorine concentrations in the ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید