نتایج جستجو برای: phantom measurements

تعداد نتایج: 381559  

Journal: :Progress in Nuclear Science and Technology 2014

A. Vahidian Kamyad, M. Hajizadeh Saffar, M. Naji Midani, M.H. Noori Eskandari,

Background: Photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of SPECT images and results to errors in accuracy of quantitative measurements. This can be corrected via different physical or mathematical approaches. As the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘Piece ...

بختیاری, مرتضی, حمیدی ابرقویی, زهره, ریاحی عالم, نادر, سرکار, سعید , شاکری, ناصر, عقابیان, محمدعلی, قاسم زاده, علی, قناعتی, حسین, لاریجانی, باقر,

Introduction & Objective : The aim of this study was to optimize MRI conventional protocols for BMD(Bone Mineral Density) measurements using MRI Relaxometry in systems not facilitated with special multi echo protocols. Since, cortical and trabecular bone separation can not be performed in DEXA, so the results might lead to erroneous interpretation of BMD values. One method for bone quality dete...

Journal: :Physical review 2021

CuO, known to be multiferroic (MF) from ${T}_{L}\phantom{\rule{4pt}{0ex}}=\phantom{\rule{4pt}{0ex}}213\phantom{\rule{4pt}{0ex}}\mathrm{K}$ ${T}_{N}\phantom{\rule{4pt}{0ex}}=\phantom{\rule{4pt}{0ex}}230\phantom{\rule{4pt}{0ex}}\mathrm{K}$ at ambient pressure, has been the subject of debates about its ability exhibit multiferroicity room temperature (RT) under high hydrostatic pressure. Here we a...

2014
Ryan D. Foster Michael P. Speiser Timothy D. Solberg

Linacs equipped with flattening filter-free (FFF) megavoltage photon beams are now commercially available. However, the commissioning of FFF beams poses challenges that are not shared with traditional flattened megavoltage X-ray beams. The planning system must model a beam that is peaked in the center and has an energy spectrum that is softer than the flattened beam. Removing the flattening fil...

Journal: :EJNMMI physics 2015
Jarmo Teuho Virva Saunavaara Mika Teräs

Turku PET Center, Turku, Finland The Philips Ingenuity TF is a sequential PET/MR with an Achieva 3T X-series MR and Gemini TF PET system connected with a rotating table. Both the PET and MR systems are designed to minimize mutual system interference. However, a longitudinal study concerning the stability of the MR system has not been conducted before. The stability of the MR system affects diff...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2013
Susanne Ziegler Harald Braun Philipp Ritt Carsten Hocke Torsten Kuwert Harald H Quick

UNLABELLED With the recent advent of integrated PET/MR hybrid systems, the need for simultaneous PET and MR phantom measurements arises. Phantom fluids that are used in stand-alone MR systems, especially in larger phantoms and at a high magnetic field strength, are not necessarily applicable in PET imaging and vice versa. In this study, different approaches to fluid selection were considered an...

2008
J. Chen J. Oudry K. Glaser V. Miette L. Sandrin R. Ehman

Fig. 1 (a) MRE wave image and Elastogram (b) UTE spatio-temporal strain map (c) Bland-Altman plot MRE: FOV=14cm,Matrix=256X64,TR/TE=50/26.5ms, flip angle=30 ̊, thickness=10cm, BW=±16kHz, continues vibration=60Hz, average stiffness of ROI drawn on the elastogram was measured as the stiffness of the phantom. UTE: center frequency of transducer=3.5 MHz, transient vibration=20ms (1 cycle of 50 Hz si...