نتایج جستجو برای: microelectrode

تعداد نتایج: 3833  

Journal: :Journal of neuroscience methods 1998
S H Fung D Burstein R T Born

To obtain more precise anatomical information about cortical sites of microelectrode recording and microstimulation experiments in alert animals, we have developed a non-invasive, magnetic resonance imaging (MRI) technique for reconstructing microelectrode tracks. We made microelectrode penetrations in the brains of anesthetized rats and marked sites along them by depositing metal, presumably i...

Journal: :Analytical chemistry 2002
Achintya N Bezbaruah Tian C Zhang

A new method for fabrication of anodically electrodeposited iridium oxide film pH microelectrodes has been developed in this study. Novel for its tip size (3-10-microm tip diameter), the microelectrode is fabricated in a tapered glass micropipet filled with a low melting point alloy. The tapered end is recessed and platinized. Thereafter, iridium oxide is electrodeposited over the platinized en...

Journal: :The Analyst 2009
Denis Menshykau Xing-Jiu Huang Neil V Rees F Javier del Campo Francesc Xavier Muñoz Richard G Compton

Microelectrode arrays find broad application in electroanalysis offering the enhanced sensitivity associated with microelectrodes, but with a high total current output. Such arrays are often constructed to make the electrodes 'diffusionally independent'. To emphasize that this is a time dependent property, a two-dimensional simulation, in conjunction with the diffusional domain approach, is use...

Journal: :AIP Advances 2021

We analyze the extracellular stimulation current and charge injection capacity (CIC) of microelectrodes coated with an insulating layer to prevent toxic electrochemical effects in bioelectronic applications. show for a microelectrode ferroelectric that polarization contributes current. Depending on remanent Pr ferroelectric, switching regime can increase CIC by up two orders magnitude as compar...

Journal: :Advanced biology 2021

In article number 2000223, Silvia Ronchi, Michele Fiscella, and co-workers show neurons plated on a high-density microelectrode array. The small electrode size the tight spacing between 26 400 electrodes enable functional extracellular electrophysiological characterization of across scales, from subcellular-resolution features, like axons dendrites, through individual neuronal cells to entire n...

2012
Austin A. Browne Michael J. O’Donnell

The transport of ammonia by various tissues throughout the body is of fundamental importance for nitrogen excretion in invertebrates, yet sites and mechanisms of ammonia transport are not presently well understood. In this thesis a novel ammonium-selective microelectrode was developed using the crown ether ionophore TD19C6, which is approximately 3800-fold more selective for NH 4 + than Na + co...

2016
Honglei Guo Takayuki Kurokawa Masakazu Takahata Wei Hong Yoshinori Katsuyama Feng Luo Jamil Ahmed Tasuku Nakajima Takayuki Nonoyama Jian Ping Gong

We report, for the first time, the quantitative measurement of the local electric potential of brittle polyelectrolyte hydrogels using the microelectrode technique (MET). Given the solid-like nature of the hydrogels, the difficulty of applying MET is how to make a good contact of the microelectrode to the hydrogel. Poor local contact substantial underestimates the potential. We observed that, t...

Journal: :Analytical chemistry 2010
Fernando Cortés-Salazar Dmitry Momotenko Andreas Lesch Gunther Wittstock Hubert H Girault

A linear array of eight individual addressable microelectrodes has been developed in order to perform high-throughput scanning electrochemical microscopy (SECM) imaging of large sample areas in contact regime. Similar to previous reports, the soft microelectrode array was fabricated by ablating microchannels on a polyethylene terephthalate (PET) film and filling them with carbon ink. Improvemen...

2016
Nan Rong Baoqing Shan Chao Wang

A study coupling sedimentcore incubation and microelectrode measurement was performed to explore the sediment oxygen demand (SOD) at 16 stations in the Ziya River Watershed, a severely polluted and anoxic river system in the north of China. Total oxygen flux values in the range 0.19-1.41 g/(m²·d) with an average of 0.62 g/(m²·d) were obtained by core incubations, and diffusive oxygen flux value...

Journal: :The Journal of Cell Biology 1977
I I Geschwind J M Horowitz G M Mikuckis R D Dewey

Selective dispersion of melanosomes was often observed after iontophoretic injection of cyclic adenosine monophosphate (AMP) from a glass microelectrode positioned in a target melanophore in frog skin (as viewed from above through a microscope), with other melanophores in the field serving as controls. Because the skin has orderly arrays of several types of closely spaced cells, it is probable ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید