نتایج جستجو برای: glass micro

تعداد نتایج: 185123  

Journal: :Journal of biomedical materials research 1996
O Peitl Filho G P LaTorre L L Hench

The bioactive glass 45S5 was crystallized to 8-100 vol % of crystals by thermal treatments from 550-680 degrees C. The micro-structure of the glass-ceramics had a very uniform crystal size, ranging from 8 to 20 microns. Fourier-transform infrared (FTIR) spectroscopy was used to determine the rate of hydroxycarbonate apatite (HCA) formation that occurs on bioactive glass and glass-ceramic implan...

2008
Dae Jin Yun Tae Il Seo Dong Sam Park

For microfabrications of biochips with micro fluidic channels, a large number of microfabrication techniques based on silicon or glass-based Micro-Electro-Mechanical System (MEMS) technologies were proposed in the last decade. In recent years, for low cost and mass production, polymer-based microfabrication techniques by microinjection molding and micro hot embossing have been proposed. These t...

B. Eftekhari Yekta, G. Maghouli,

Commercial dental lithium disilicate based glass-ceramics containing various amounts of P2O5 were synthesized. Regarding the crystallization behavior and physico-chemical properties of the glasses, the optimum percent of P2O5 was determined.as 8 %wt. Crystallization behavior of the glasses was investigated by X-ray diffraction (XRD) and differential thermal analysis (DTA). The micro-hardness a...

Journal: :The Japanese journal of physiology 1964
S HIRAKAWA H YOSHIMURA

The use of micro-glass electrodes sensitive to the activity of selected cations has permitted a direct measurement of intracellular ionic activity , e. g., the activity of hydrogen ion in a single crab muscle fiber (CALDWELL 1954), and in a single squid giant axon (CALDWELL 1958, SPYROPOULOS 1960), the activity of sodium and potassium ion in a single squid giant axon (HINKE 1960). With a micro-...

Journal: :The Journal of veterinary medical science 2000
K Takase Y Murakawa S Eriguchi H Fujikawa

The MET95 strain of a lentogenic Newcastle disease virus (NDV) isolated from a broiler in Japan, showed unique hemagglutination (HA) activity. The MET95 strain failed to show HA when examined by rapid glass plate method although they showed HA titer of 1:1,024 by micro-plate method. This unique HA was also observed after the MET95 strain was passaged ten times in chickens. The failure of HA by ...

2016
Tihana Repić Katarina Madirazza Ezgi Bektur Damir Sapunar

Our study focuses on characterization of dorsal root ganglion (DRG) neurons cultured on silicon micro-pillar substrates (MPS) with the ultimate goal of designing micro-electrode arrays (MEAs) for successful electrophysiological recordings of DRG neurons. Adult and neonatal DRG neurons were cultured on MPS and glass coverslips for 7 days in vitro. DRG neuronal distribution and morphometric analy...

Journal: :Lab on a chip 2011
Rerngchai Arayanarakool Lingling Shui Albert van den Berg Jan C T Eijkel

This work reports a new method to hydrophobize glass-based micro- and nanofluidic networks. Conventional methods of hydrophobizing glass surfaces often create particulate debris causing clogging especially in shallow nanochannels or require skilful handling. Our novel method employs oxygen plasma, silicone oil and ultraviolet (UV) light. The contact angle of the modified bare glass surface can ...

2016
Renxin Wang Bing Bai Hengzhen Feng Ziming Ren Huiliang Cao Chenyang Xue Binzhen Zhang Jun Liu

Electrostatic driving and capacitive detection is widely used in micro hemispheric shell resonators (HSR). The capacitor gap distance is a dominant factor for the initial capacitance, and affects the driving voltage and sensitivity. In order to decrease the equivalent gap distance, a micro HSR with annular electrodes fabricated by a glassblowing method was developed. Central and annular cavitie...

Journal: :Lab on a chip 2005
P Mela S Onclin M H Goedbloed S Levi M F Garcia-Parajo N F van Hulst B J Ravoo D N Reinhoudt A van den Berg

This paper describes the integration of opto-chemosensors in microfluidics networks. Our technique exploits the internal surface of the network as a platform to build a sensing system by coating the surface with a self-assembled monolayer and subsequently binding a fluorescent sensing molecule to the monolayer. Fluorescent molecules were used that can switch between a fluorescent and a non-fluo...

Journal: :Nucleic acids research 1996
W L Ng M Schummer F D Cirisano R L Baldwin B Y Karlan L Hood

We have developed a reliable high-throughput plasmid isolation system using a 96-well plate format. This system combines a novel glass bead micro-mixing method with modified alkaline lysis and Sephacryl S-500 DNA purification procedures. Mechanical forces generated by vortexing glass beads inside each well of the 96-well plates ensure that the bacterial pellets are homogeneously resuspended, th...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید