A pelvimetry examination is sometimes prescribed to a pregnant woman at the end of her pregnancy in order assess dimensions pelvis prior childbirth. This has long been performed by using X-ray, but now increasingly being replaced CT-scan The objective this study radiation doses received during practical CT Hitashi Supria 16-slice scanner. were estimated Monte Carlo (MC)-based simulation with GA...
Introduction In computed tomography (CT) technology, an optimal radiation dose can be achieved via changing radiation parameters such as mA, pitch factor, rotation time and tube voltage (kVp) for diagnostic images. Materials and Methods In this study, the brain, abdomen, and thorax scaning was performed using Toshiba 16-slice scannerand standard AAPM and CTDI phantoms. AAPM phantom was used for...
Background: In CT systems, the machine utilizes a bowtie filter to shape the X-ray beam and remove lower energy photons. The shape of this bowtie filter is complicated and its geometry is often not available in detail. These renders the CT dose index (CTDI) to have different values in measurement versus Monte Carlo simulation studies and other analytical calculations especially in dosimetry of ...
پژوهش حاضر بررسی رابطه انعطافپذیری خانواده و سبکهای هویت با نقش واسطهگری گرایش به تفکر انتقادی در دختران نوجوان میباشد. بدینمنظور 306 نفر از دانشآموزان دختر دبیرستانهای شهر کازرون به شیوه نمونهگیری خوشهای بهوسیله پرسشنامههای گرایش به تفکر انتقادی (ctdi، ریکتس، 2003)، پرسشنامه سبکهای هویت برزونسکی (1989) و انعطافپذیری مثبت شاکری (1382) مورد آزمون قرار گرفتند. یافتههای حاصل از ت...
introduction in computed tomography (ct) technology, an optimal radiation dose can be achieved via changing radiation parameters such as ma, pitch factor, rotation time and tube voltage (kvp) for diagnostic images. materials and methods in this study, the brain, abdomen, and thorax scaning was performed using toshiba 16-slice scannerand standard aapm and ctdi phantoms. aapm phantom was used for...
The purpose of this work was to evaluate computed tomography simulators used in radio-therapy treatment planning Serbia, Croatia, and Bosnia Herzegovina. A survey quality assurance programmes 24 16 facilities conducted. dedicated CT-to-ED phantom scanned at 120 kV 140 kV, obtain conversion curves as well CTDIvol. Thoracal phantoms were the standard extended field view dosimetric effect on deliv...
Imaging dose in radiation therapy has traditionally been ignored due to its low magnitude and frequency in comparison to therapeutic dose used to treat patients. The advent of modern, volumetric, imaging modalities, often as an integral part of linear accelerators, has facilitated the implementation of image-guided radiation therapy (IGRT), which is often accomplished by daily imaging of patien...
During Computed Tomography (CT) scan examinations, it is important to ensure a good diagnosis by providing the maximum information detect pathologies and this can be done with reduced dose. In respect, several methods of dose reduction have been studied evaluated. This work investigates effect tube voltage while varying current on image quality radiation at Chest CT examination. study was condu...
conclusion scout views may be useful in determining dose and image quality in ct scanning; however, it is necessary to first determine the most appropriate scout view for ct scans. background while using the automatic exposure control technique in computed tomography (ct), the scout view determines the radiation dose for the ct scan by taking anatomical morphology into consideration. objectives...
Diagnostic radiology has undergone profound changes in the last 30 years. New technologies are available to the dental field, cone beam computed tomography (CBCT) as one of the most important. CBCT is a catch-all term for a technology comprising a variety of machines differing in many respects: patient positioning, volume size (FOV), radiation quality, image capturing and reconstruction, image ...