Yong Yang Lei Xing Arthur L Boyer Yixin Song Yimin Hu

Accurate determination of the head scatter factor Sc is an important issue, especially for intensity modulated radiation therapy, where the segmented fields are often very irregular and much less than the collimator jaw settings. In this work, we report an Sc calculation algorithm for symmetric, asymmetric, and irregular open fields shaped by the tertiary collimator (a multileaf collimator or b...

Journal: :Journal of Instrumentation 2021

This paper presents the first determination of spatial resolution ANET Compact Neutron Collimator, obtained with a measuring campaign at LENA Mark-II TRIGA reactor in Pavia. novel collimator consists sequence collimating and absorbing channels organised chessboard-like geometry. It has scalable structure both length field view. is characterized by an elevated collimation power within limited le...

Journal: :journal of medical signals and sensors 0
abdolreza hashemian mohammad taghi bahreyni toossi shahrokh nasseri

multileaf collimator (mlc) is among the radiation field shaping systems used for conformal radiotherapy and intensity modulation radiation therapy techniques. the mlc system that has been designed and fabricated in this study includes 52 leaves, 52 stepper motors, 2 dc motors, 16 programmable logic controllers (plcs) and one human machine interface (hmi). this system can be mounted on conventio...

2011
Tuija Kangasmaa Antti Sohlberg Jyrki T. Kuikka

Poor resolution of single photon emission computed tomography (SPECT) has degraded its use in clinical practice. Collimator correction has been shown to improve the reconstructed resolution, but the correction can generate ringing artefacts, which lower image quality. This paper investigates whether Bayesian reconstruction methods could reduce these artefacts. We have applied and tested three B...

2002
H Roos M Kellerer

An a irradiation device is described that utilises a commercially available disc-shaped americium-241 source of 8 cm diameter. The a particles traverse a moving collimator and the source is rotated to reduce the influence of source inhomogeneities. Source, collimator and a shutter disc are mounted in a container which is flushed with helium to reduce energy losses of the a particles before reac...

Journal: :journal of medical signals and sensors 0
mohammad-taghi bahreyni-toosi shahrokh nasseri mahdi momennezhad fatemeh hasanabadi hamid gholamhosseinian

the aim of this study is to provide a control software system, based on monte carlo simulation, and calculations of dosimetric parameters of standard and wedge radiation fi elds, using a monte carlo method. gate version 6.1 (opengate collaboration), was used to simulate a compact 6 mv linear accelerator system. in order to accelerate the calculations, the phase-space technique and cluster compu...

2018
Georg A. Weidlich M. Bret Schneider John R. Adler

Introduction The ZAP-X is a novel self-contained and first-of-its-kind self-shielded therapeutic radiation device dedicated to brain and head and neck radiosurgery. By utilizing a 2.7-MV linear accelerator and incorporating a design in which a beam stop and major mechanical elements serve a radiation shielding function, the Zap-X does not typically require a radiation bunker. The unique collima...

Journal: :Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms 2022

In order to have highly flexible secondary beamlines collimation is crucial. Collimators are blocks of material placed along the beamline that let main beam pass within collimator aperture limits, while most particles beyond it interact in and gets absorbed or loses enough energy be deflected away from core by magnets downstream. Some can at edge collimators accepted beam, creating background f...

2009
Liling Xiao Cho-Kuen Ng Jeffery Claiborne Fritz Caspers

A rotatable collimator is proposed for the LHC phase II collimation upgrade. When the beam crosses the collimator, it will excite trapped modes that can contribute to the beam energy loss and power dissipation on the vacuum chamber wall. Transverse trapped modes can also generate transverse kicks on the beam and may thus affect the beam quality. In this paper, the parallel eigensolver code Omeg...