نتایج جستجو برای: ti contact

تعداد نتایج: 196715  

Journal: :Langmuir : the ACS journal of surfaces and colloids 2007
Guifeng Li Shishir Prasad Ali Dhinojwala

We have used dynamic interfacial tension measurements to understand the structure of the ordered monolayer at the hexadecane/water interface induced by the presence of surfactant molecules. No abrupt changes in the interfacial tension (gamma) are observed during the expansion and contraction cycle below the interfacial ordering temperature (Ti) as observed for alkanes in contact with air. The l...

Journal: :The International journal of oral & maxillofacial implants 2001
Y J Lim Y Oshida C J Andres M T Barco

The attachment of cells to titanium surfaces is an important phenomenon in the area of clinical implant dentistry. A major consideration in designing implants has been to produce surfaces that promote desirable responses in the cells and tissues. To achieve these requirements, the titanium implant surface can be modified in various ways. This research was designed to elucidate the relationship ...

Journal: :Biomaterials 2010
Cheol-Min Han Eun-Jung Lee Hyoun-Ee Kim Young-Hag Koh Keung N Kim Yoon Ha Sung-Uk Kuh

The surface of polyetheretherketone (PEEK) was coated with a pure titanium (Ti) layer using an electron beam (e-beam) deposition method in order to enhance its biocompatibility and adhesion to bone tissue. The e-beam deposition method was a low-temperature coating process that formed a dense, uniform and well crystallized Ti layer without deteriorating the characteristics of the PEEK implant. T...

Journal: :Biointerphases 2015
Laura Burgos-Asperilla Jose Luis Garcia Fierro Miriam Gamero Maria Lorenza Escudero Concepción Alonso Maria Cristina García-Alonso

Micromotion and fretting wear between bone and Ti-based alloys in stem and dental implants breaks the passive film and exposes the metal to the action of the complex surrounding medium, generating substantial amounts of debris and continuous Ti ion release. In this work, oxidation treatments at low temperatures (277 °C, 5 h) have been used to promote the formation of wear-corrosion resistant ti...

2014
Maria Politou Enlong Liu Inge Asselberghs ChangSeung Lee Koen Martens Zsolt Tokei Cedric Huyghebaert Stefan De Gendt Marc Heyns

In this work, a systematic study of the graphene/metal contact resistance (RC) is conducted. The circular Transfer Length Method (cTLM) is used to determine the RC values with several metals. Samples with Cu, Ti, Ni, Pt, Ag, Pd and Au contacts were fabricated and electrically characterized. Our results indicate that noble metals show lower RC. The lowest RC was observed for Au samples (~2.3kΩ.μ...

2006
T. A. VENKATESH B. P. CONNER C. S. LEE A. E. GIANNAKOPOULOS T. C. LINDLEY S. SURESH

A systematic investigation of the fretting fatigue behavior of the titanium alloy Ti-6Al-4V in both the mill-annealed (MA) and the solution-treated and overaged (STOA) conditions was carried out. A sphere-on-flat fretting fatigue device was used that facilitated real-time control and monitoring of all the relevant parameters such as the contact geometry, contact (normal and tangential) loads, a...

Journal: :Cells, tissues, organs 2005
Thomas K Monsees K Barth S Tippelt K Heidel A Gorbunov W Pompe R H W Funk

To test nanosize surface patterning for application as implant material, a suitable titanium composition has to be found first. Therefore we investigated the effect of surface chemistry on attachment and differentiation of osteoblast-like cells on pure titanium prepared by pulsed laser deposition (TiPLD) and different Ti alloys (Ti6Al4V, TiNb30 and TiNb13Zr13). Early attachment (30 min) and alk...

Journal: :Brazilian dental journal 2013
Luiz Guilherme P Soares Edival Barreto de Júnior Magalhães Cesar Augusto B Magalhães Cimara Fortes Ferreira Aparecida Maria C Marques Antônio Luiz B Pinheiro

Use of biomaterials and light on bone grafts has been widely reported. This work assessed the influence of low-level laser therapy (LLLT) on bone volume (BV) and bone implant contact (BIC) interface around implants inserted in blocks of bovine or autologous bone grafts (autografts), irradiated or not, in rabbit femurs. Twenty-four adult rabbits were divided in 8 groups: AG: autograft; XG: xenog...

Journal: :Materials transactions 2021

The artificial hip joints have galvanic couple between femoral head made of CoCr alloy and stem Ti or alloy, are subjected to high levels mechanical stress. Therefore, tribocorrosion has been frequently reported. In this study, we performed the first electrochemical numerical simulation for with friction in simulated body fluid. We constructed single metal model investigate effect cathodic reac...

Journal: :Korean Journal of Materials Research 2010

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید