نتایج جستجو برای: tg 43 dosimetric parameters

تعداد نتایج: 690233  

M. Sohrabpour, N. Babaei Bidmeshki, S.R. Mahdavi,

Background: The purpose of this project was to derive the brachytherapy dosimetric functions described by American Association of Physicists in Medicine (AAPM) TG-43 U1 based on high dose rate 192I sources. Materials and Methods: The method utilized included both simulation of the designed Polymethyl methacrylate (PMMA) phantom using the Monte Carlo of MCNP4C and benchmarking of the simulation ...

Journal: :iranian journal of radiation research 0
f. taghdiri department of nuclear engineering, science and research branch, islamic azad university, tehran, iran m. sadeghi agricultural, medical and industrial research school, nuclear science and technology research institute, karaj, iran s.h. hosseini department of nuclear engineering, science and research branch, islamic azad university, tehran, iran m. athari department of nuclear engineering, science and research branch, islamic azad university, tehran, iran

background: the formalism recommended by task group 60 (tg-60) of the american association of physicists in medicine (aapm) is applicable for β sources. radioactive biocompatible and biodegradable 153sm glass seed without encapsulation is a β- emitter with a short half life and delivers a high dose rate to the tumor in the millimeter range. in this work the dosimetry parameters of the seed for ...

2012
Mohammad Taghi Bahreyni Toossi Mahdi Ghorbani Ali Asghar Mowlavi Ali Soleimani Meigooni

BACKGROUND Dosimetric characteristics of a high dose rate (HDR) GZP6 Co-60 brachytherapy source have been evaluated following American Association of Physicists in MedicineTask Group 43U1 (AAPM TG-43U1) recommendations for their clinical applications. MATERIALS AND METHODS MCNP-4C and MCNPX Monte Carlo codes were utilized to calculate dose rate constant, two dimensional (2D) dose distribution...

Journal: :iranian journal of radiation research 0
s.r.m. mahdavi department of medical physics, tehran university of medical sciences, tehran, iran m. mahdavi department of physics, faculty of basic sciences, mazandaran university, babolsar, iran h. alijanzadeh department of physics, faculty of basic sciences, mazandaran university, babolsar, iran m. zabihzadeh department of medical physics, joundishapour university of medical sciences, ahvaz, iran a. mostaar department of medical physics, faculty of medicine, shahid beheshti university of medical sciences, tehran, iran

background: two protocols of aapm tg-51 and iaea trs-398 were compared followed by a measurement and monte carlo simulation of beam quality correction factor, kq, aapm tg-51 and iaea trs-398 protocols were compared for the absorbed dose to water for dw, and kq parameters. materials and methods: dose measurements by either protocols were performed with cylindrical and plane parallel chambers for...

Background: HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed. Due to high dose rate and tumor location, accuracy evaluation of treatment planning system (TPS) is particularly important. Common methods used in TPS dosimetry are based on computat...

Journal: :Medical physics 2012
Luc Beaulieu Asa Carlsson Tedgren Jean-Francois Carrier Stephen D Davis Firas Mourtada Mark J Rivard Rowan M Thomson Frank Verhaegen Todd A Wareing Jeffrey F Williamson

The charge of Task Group 186 (TG-186) is to provide guidance for early adopters of model-based dose calculation algorithms (MBDCAs) for brachytherapy (BT) dose calculations to ensure practice uniformity. Contrary to external beam radiotherapy, heterogeneity correction algorithms have only recently been made available to the BT community. Yet, BT dose calculation accuracy is highly dependent on ...

2012
Mehdi Zehtabian Reza Faghihi Sedigheh Sina

In 1995, the American Association of Physicists in Medicine (AAPM)) published a report on the dosimetry of sources used in interstitial brachytherapy, Task Group No. 43 (TG-43) (Nath et al., 1995). This report introduces dose calculation formalism utilizing new quantities like air kerma strength (SK), dose rate constant (Λ), geometry function (G (r,θ)), radial dose function (g (r)), and anisotr...

2017
Mehdi Zehtabian Reza Faghihi Sedigheh Sina

A. Mostaar, H. Alijanzadeh, M. Mahdavi, M. Zabihzadeh, S.R.M. Mahdavi,

Background: Two protocols of AAPM TG-51 and IAEA TRS-398 were compared followed by a measurement and Monte Carlo simulation of beam quality correction factor, KQ, AAPM TG-51 and IAEA TRS-398 protocols were compared for the absorbed dose to water for DW, and KQ parameters. Materials and Methods: Dose measurements by either protocols were performed with cylindrical and plane parallel ch...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید