نتایج جستجو برای: insulated wire
تعداد نتایج: 33751 فیلتر نتایج به سال:
A technique has been developed for fabricating three dimensional "hair brush" electrode arrays from monocrystalline silicon blocks. Arrays consist of a square pattern of 100 penetrating electrodes, with 400 microns interelectrode spacing. Each electrode is 1.5mm in length and tapers from about 100 microns at its base to a sharp point at the tip. The tips of each electrode are coated with platin...
The design of cryogenic propellant tanks that are used for storing liquid hydrogen and liquid oxygen due to the low boiling temperature has many differences compared with the others. In this paper, the most important insulated systems in cryogenic storage tanks, such as vacuum insulated, vacuum insulated with powder, vacuum insulated with radiation shields, multilayer super insulation an...
In this study, the possibility of using a combination of gravel filters with plastic cover to increase water infiltration and soil moisture storage in rainwater catchment systems was investigated. For this purpose, five treatments (with three replications) including control treatment, vegetation removal with filter, vegetation removal without filter, semi-insulated system with filter, an...
The platinum butadiynyl complex trans-(C(6)F(5))(p-tol(3)P)(2)Pt(C≡C)(2)H and a CuI adduct of a 1,10-phenanthroline based 33-membered macrocycle react in the presence of K(2)CO(3) and I(2) or O(2) to give a rotaxane (ca. 9%) in which the macrocycle is threaded by the sp carbon chain of trans,trans-(C(6)F(5))(p-tol(3)P)(2)Pt(C≡C)(4)Pt(Pp-tol(3))(2)(C(6)F(5)). The crystal structure and macrocycle...
This paper aims to evaluate a Type-II insulated wire (i.e., Glass fibre wire) as function of thermal ageing time based on partial discharges (PD) activity. Partial discharge inception voltage (PDIV), extinction (PDEV), and repetitive (RPDIV) measurements have been performed both unaged thermally aged specimens. Each specimen modelled the turn-to-turn insulation; hence it was made by pair wires ...
Bond wire lift-off is one of the major failure mechanisms in insulated gate bipolar transistor (IGBT) modules. Detecting fault bond wires important to avoid open-circuit IGBT ensure reliable operation power converters. In this paper, we propose a novel fatigue detection method for IGBT, which could be used normal working conditions. Firstly, investigated dependence on heatsink thermal resistanc...
H. Bassen, A. Kam, W. Kainz, G. Mendoza, H. Wang Center for Devices and Radiological Health, Food and Drug Administration, Rockville, MD, United States, Diagnostic Radiology Department, National Institutes of Health, Bethesda, MD, United States Introduction – Potentially dangerous heating occurs at the narrow tip of certain medical implants in patients being imaged by standard MRI systems [1, 2...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید