نتایج جستجو برای: gyn brachytherapy phantom

تعداد نتایج: 25431  

Background: Recent studies in eye plaque brachytherapy have shown a considerable difference between the dosimetric results using water phantom and a model of human eye containing realistic materials. In spite of this fact, there is a lack of simulation studies based on such a model in proton therapy literatures. In the presented work, the effect of utilizing an eye model with ocular media on pr...

Journal: :Medical physics 2013
Kevin E Casey Paola Alvarez Stephen F Kry Rebecca M Howell Ann Lawyer David Followill

PURPOSE The aim of this work was to create a mailable phantom with measurement accuracy suitable for Radiological Physics Center (RPC) audits of high dose-rate (HDR) brachytherapy sources at institutions participating in National Cancer Institute-funded cooperative clinical trials. Optically stimulated luminescence dosimeters (OSLDs) were chosen as the dosimeter to be used with the phantom. M...

Journal: :journal of biomedical physics and engineering 0
s sina radiation research center, shiraz university, shiraz, iran r faghihi a s meigooni

background: most of the current brachytherapy treatment planning systems (tps) use the tg-43u1 recommendations for dosimetry in water phantom, not considering the heterogeneity effects. objective: the purpose of this study is developing a method for obtaining correction factors for heterogeneity for cs-137 brachytherapy sources based on pre-calculated mc simulations and interpolation. method: t...

ژورنال: سنجش و ایمنی پرتو 2016

The determination of the dosimetry parameters of brachytherapy in the treatment of cancerous tumors as per the TG-43U1 protocol provided by the American Association of Physicists in Medicine should be done in the surrounding water source before clinical application. To achieve a good treatment result, various factors such as body tissues with different densities can have a decisive role so that...

Journal: :Medical physics 2009
Malik Brunet-Benkhoucha Frank Verhaegen Stéphanie Lassalle Dominic Béliveau-Nadeau Brigitte Reniers David Donath Daniel Taussky Jean-François Carrier

PURPOSE The low dose rate brachytherapy procedure would benefit from an intraoperative postimplant dosimetry verification technique to identify possible suboptimal dose coverage and suggest a potential reimplantation. The main objective of this project is to develop an efficient, operator-free, intraoperative seed detection technique using the imaging modalities available in a low dose rate bra...

Journal: :Physics in medicine and biology 2013
Antony L Palmer Chris Lee Ailsa J Ratcliffe David Bradley Andrew Nisbet

A novel phantom is presented for 'full system' dosimetric audit comparing planned and delivered dose distributions in HDR gynaecological brachytherapy, using clinical treatment applicators. The brachytherapy applicator dosimetry test object consists of a near full-scatter water tank with applicator and film supports constructed of Solid Water, accommodating any typical cervix applicator. Film d...

2015
K. Hadad M. Zohrevand R. Faghihi A. Sedighi Pashaki

BACKGROUND HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed. Due to high dose rate and tumor location, accuracy evaluation of treatment planning system (TPS) is particularly important. Common methods used in TPS dosimetry are based on computati...

2015
Amir M. Owrangi Shruti Jolly James M. Balter Yue Cao Katherine E. Maturen Lisa Young Tong Zhu Joann I. Prisciandaro

We present an institutional experience on the clinical implementation of magnetic resonance (MR)-guided vaginal brachytherapy using commercially available solid applicator models. To test the fidelity of solid applicator models to digitize vaginal cylinder applicators, three datasets were evaluated. The first included 15 patients who were simulated with CT alone. Next, a water phantom was used ...

2008
A. A. Mowlavi F. Cupardo M. Severgnini

Theoretical and experimental studies have been applied for dosimetric parameters determination of the brachytherapy sources (1-3). Usually, Monte Carlo method has been used to define such quantities as the anisotropy dose function, the radial dose function, and the dose calculation close to the source in brachytherapy (4-6). Ir source is used widely in brachytherapy to treat localized tumors ne...

Journal: :Medical physics 2008
Douglas Pfeiffer Steven Sutlief Wenzheng Feng Heather M Pierce Jim Kofler

While ultrasound guided prostate brachytherapy has gained wide acceptance as a primary treatment tool for prostate cancer, quality assurance of the ultrasound guidance system has received very little attention. Task Group 128 of the American Association of Physicists in Medicine was created to address quality assurance requirements specific to transrectal ultrasound used for guidance of prostat...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید