نتایج جستجو برای: electro elution
تعداد نتایج: 27067 فیلتر نتایج به سال:
objective: in this article, a numerical study is conducted on mixing of two fluids in the liquid phase with two different concentrations of a chemical species in the electro-osmotic flow. methods: the base liquid is an electrolyte which flows in a two-dimensional micro-channel having electrically charged walls. lorentz electric force, which is used as stimulating flow factor, is created by appl...
the performance of a plug flow electrocoagulation reactor for the treatment of cattle abattoir(slaughterhouse) wastewater was investigated. a cylindrical iron reactor was operated as a cathode at arecycling batch mode while three iron rods located at the center of the reactor were used as an anode. theeffects of different parameters, including the current density, the supporting electrolyte dos...
Antibiotic-loaded bone cement (ALBC) is widely used in orthopaedic surgery for both prevention and treatment of infection. Little is known about the effect of different brand combinations of antibiotic and bone cement on the elution profile and mechanical strength of ALBC. Standardized specimens that consisted of one of the 4 brands of bone cement and one of the 3 brands of vancomycin were fash...
Electro-osmosis in clayey soils and sediments, for purposes of clay consolidation, dewatering, or cleanup, and electro injection in porous media is widespread recent decades. It is experimentally found that the chemical properties of porous media especially PH change the characteristics of media. Electro-osmotic conductivity is a function of soil and grout material chemistry, altering with time...
The antimicrobial properties and the elution characteristics of gentamicin-vancomycin-loaded hip spacers were studied in vivo and in vitro. Vancomycin elution was greater than gentamicin elution. The antibiotic concentrations in vivo were less than those in vitro. Not dependent on implantation duration, growth inhibition by spacers in vitro was observed for 2 weeks. The reason for protracted wo...
The efficiency of poliovirus elution from fiber glass cartridge filters (K27), epoxy-fiber glass-asbestos filters (M780), and pleated cartridge filters was assessed by using 3% beef extract (pH 9.0) or 0.1 M glycine (pH 11.5). Poliovirus type I, strain LSc, was seeded into 20- to 25-gallon (ca. 75.6- to 95.6-liter) samples of treated sewage effluent and concentrated by using a filter adsorption...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید