In the current research, hydroxyapatite samples, synthesized by hydrothermal methods was studied from the perspective of thermoluminescence dosimetry. The results of the study were compared and studied with different aspects of dosimetry, including dose-response variations of synthesized samples, degree of its linearity, and the percentage of response fading, as well as the position of the main...
In this research MgSO4:Cu nanoparticles was synthesized for the first time by hydrothermal method. The size of the produced nanoparticles calculated by scherrer equation was about 36 nm using XRD pattern which was in agreement with that of SEM analysis. Thermoluminescence (TL) properties of the MgSO4:Cu nanoparticles was investigated in gamma irradiation by 60Co source. Optimum amount of impuri...
Metal oxide semiconductor field effect transistor (MOSFET) detectors have recently been introduced to radiation therapy. However, the response of these detectors is known to vary with dose rate. Therefore, it is important to evaluate how much variation between the treatment prescribed dose and the dose that is actually delivered to the patient using high-energy photon or electron beams under co...
We proposed to perform a basic dosimetry commissioning on a new imager sys-tem, the Varian aS1200 electronic portal imaging device (EPID) and TrueBeam 2.0 linear accelerator for flattened (FF) and flattening filter-free (FFF) beams, then to develop an image-based quality assurance (QA) model for verification of the system delivery accuracy for intensity-modulated radiation therapy (IMRT) treat-...
Magnesium silicate has been prepared by a precipitation technique. This composite structure was proven different tools, XRD, TGA&DTA, FTIR, and XRF. found to have the formulas Mg1.1SiO3.2.1.1H2O. Thermoluminescence (TL) dosimetric properties like (linearity, fading, energy independence) of magnesium in shape MgSiO3 estimated. A strong TL dosimetry peak associated with gamma radiation arises fro...
The ORIGIN project targets the production and qualification of a real-time radiation dose imaging source localization system for both Low Dose Rate (LDR) High (HDR) brachytherapy treatments, namely radiotherapy based on use radioactive sources implanted in patient’s body. This goal will be achieved through 16-fiber sensor system, engineered to house clear-fiber tip small volume scintillator all...