نتایج جستجو برای: artisan iol

تعداد نتایج: 2687  

2012
Jagat Ram Nishant Gupta Manish Chaudhary Jaspreet Singh Sukhija Amit Gupta Jaidrath Kumar

Objective: To report opacification of hydrophilic acrylic and silicone foldable intraocular lenses (IOL). Designs: Case series. Participants: Five patients with IOL opacification. Results: We report five eyes of five patients with late opacification of the intraocular lens (IOL). Three patients had hydrophilic acrylic (SC60B-OUV-MDR, Inc), two had silicone IOL (Allergan SI30NB). Two out of the ...

Journal: :Journal of cataract and refractive surgery 2009
Niels E de Vries Nayyirih G Tahzib Camille J Budo Carroll A B Webers Ruben de Boer Fred Hendrikse Rudy M M A Nuijts

PURPOSE To report the results of cataract surgery after previous implantation of an Artisan iris-fixated phakic intraocular lens (pIOL) for the correction of myopia. SETTING University center and private practice. METHODS This study comprised eyes with previous implantation of an iris-fixated pIOL to correct myopia and subsequent pIOL explantation combined with cataract surgery and in-the-b...

Journal: :Journal of cataract and refractive surgery 2012
Yueqin Chen Qinghuai Liu Chunyan Xue Zhenping Huang Yin Chen

PURPOSE To evaluate the efficacy, predictability, stability, safety, and complications of secondary anterior iris fixation of the Artisan iris-fixated intraocular lens (IOL) to correct aphakia in eyes without sufficient capsule support. SETTING Department of Ophthalmology, Jinling Hospital, School of Medicine, Nanjing University, Nanjing, China. DESIGN Cohort study. METHODS Eyes having im...

2014
Tiago Bravo Ferreira Joana Portelinha

PURPOSE To evaluate the distance between the endothelial surface of the cornea to the anterior edge of an Artiflex® phakic intraocular lens (IOL) implant to improve the safety profile of this implant. METHODS This is a retrospective clinical case series of 45 patients who had Artiflex phakic IOL implantation (Artiflex p-IOL) with a follow-up period of 3 years. A Pentacam HR imaging system was...

Journal: :European journal of ophthalmology 2007
N Jirásková P Rozsíval A Kohout

PURPOSE To evaluate the indications, lens styles, perioperative findings, and results of intraocular lens (IOL) explantation or exchange performed in the authors department in 2005. METHODS The retrospective analysis comprised 22 patients (23 eyes). Twenty-one eyes had previous phacoemulsification and IOL implantation, one eye secondary aphakic IOL, and one eye phakic IOL implantation. The in...

2010
Juan Carlos Castilla

Fishery-management policies based on the allocation of exclusive fishing rights, territorial use rights, and sea zoning are recurrent tools for achieving sustainability. In Chile, the 1991 Fishery and Aquaculture Law reformed division of the right to fish between the artisan and industrial subsectors, introduced sea-zoning (spacebased) strategies, and established a differential individual trans...

Journal: :Fetal diagnosis and therapy 2015
Núria Baños Federico Migliorelli Eduardo Posadas Janisse Ferreri Montse Palacio

OBJECTIVE The objectives of this review were to identify the predictive factors of induction of labor (IOL) failure or success as well as to highlight the current heterogeneity regarding the definition and diagnosis of failed IOL. MATERIALS AND METHODS Only studies in which the main or secondary outcome was failed IOL, defined as not entering the active phase of labor after 24 h of prostaglan...

ژورنال: بینا 2008
جوادی, محمدعلی, فرامرزی, امیر ,

هدف: مقایسه نتایج کارگذاری لنز داخل چشمی (IOL) در فضای کپسولی با کارگذاری هاپتیک لنز در فضای شیار سیلیاری و گیر انداختن (capture) اپتیک در کپسول خلفی در جراحی آب‌مروارید کودکان. روش پژوهش: هجده چشم از 9 کودک دچار آب‌مروارید مادرزادی دوطرفه در محدوده سنی 8-5/2 سال مورد مطالعه قرار گرفتند. چشم‌های هر بیمار به طور تصادفی در یکی از گروه‌ها قرار گرفت. در یک چشم (گروه کپسولی) پس از انجام کپسولورک...

Journal: :Indian Journal of Clinical and Experimental Ophthalmology 2021

One of the most common cause decrease vision in a pseudophakic patient is formation posterior capsular opacification (PCO) which affected by several factors like design implanted intraocular lens (IOL) and material IOL. PCO incidence has been reported to be 20.7% at 2 years & 28.5% 5 years. Decrease because necessitates capsulotomy with neodymium yttrium aluminum garnet (Nd-YAG) laser create sm...

2016
Jason J Jones Jeffrey Chu Jacob Graham Serge Zaluski Guillermo Rocha

PURPOSE The aim of this study was to evaluate the operational impact of using preloaded intraocular lens (IOL) delivery systems compared with manually loaded IOL delivery processes during routine cataract surgeries. METHODS Time and motion data, staff and surgery schedules, and cost accounting reports were collected across three sites located in the US, France, and Canada. Time and motion dat...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید