نتایج جستجو برای: ultc transformer

تعداد نتایج: 11492  

2000
Mladen Kezunovic Yong Guo

The modeling of power transformer faults and its application to performance evaluation of a commercial digital power transformer relay are the objective of this study. A new method to build an EMTP/ATP power transformer model is proposed in this paper. Detailed modeling of the transformer relay is also discussed. The transient waveforms generated by ATP under different operating conditions are ...

2015
D. Vidal J. Pedra

Airport ground lighting (AGL) systems provide visual reference to aircrafts during airport operations. In AGL systems, constant current regulators feed a beacon circuit supplied through isolation transformers. Component modeling is necessary to simulate AGL systems, and thus characterize and predict their behavior. This paper presents an isolation transformer model including transformer core sa...

2013
Neelam Choudhary Ranjana Nigam Singh

In transformers the main consequence of harmonic currents is an increase in losses, mainly in windings, because of the deformation of the leakage fields. Higher losses means that more heat is generated in the transformer so that the operating temperature increases, leading to deterioration of the insulation and a potential reduction in lifetime. This paper includes the effects of non-sinusoidal...

2013
Yan Li Yanchao gao Longnv Li Di Zhang Fangxu Han

DC bias current flowing into the neutral point of power transformer will seriously affect the normal operation of AC power system. In this paper, exciting current, harmonic component of the excitation current, magnetic flux density and noise of transformer were analyzed when the transformer is in the no-load operation state based on field-circuit coupled method. Through the calculation and anal...

The phenomenon of magnetizing inrush is a transient condition, which occurs primarily when a transformer is energized. The magnitude of inrush current may be as high as ten times or more times of transformer rated current that causes malfunction of protection system. So, for safe running of a transformer, it is necessary to distinguish inrush current from fault currents. In this paper, an equiv...

2014
Saurabh Shrivastava Ashfaque Khan Amita Mahor

Energizing of large power transformers is considered a critical event in the operation of an electric power system. When a transformer is energized by the grid or utility, it takes very high value current known as inrush current, the typical value of this current could be ten times. This inrush causes many problems like mechanical stress on transformer & harmonics injection to generator winding...

Journal: :The Review of scientific instruments 2007
Mingsen Guo K H Lam S Wang K W Kwok Helen L W Chan X Z Zhao

In this study, a modified disk-shaped multiple-output piezoelectric transformer operated at the fundamental radial vibration mode has been presented. A derived equivalent circuit for the multioutput piezoelectric transformer was used to analyze the performance. Two piezoelectric transformers, a symmetrically electroded piezoelectric transformer with dual outputs and an asymmetrically electroded...

2013

For flyback coverters, the transformer is the most important factor that determines the performance such as the efficiency, output regulation and EMI. Contrary to the normal transformer, the flyback transformer is inherently an inductor that provides energy storage, coupling and isolation for the flyback converter. In the general transformer, the current flows in both the primary and secondary ...

2013
Xin-Huai Wang Li Zhang Yin Xu Yan-Fu Bai Cheng Liu Xiaowei Shi

In this paper, a compact tri-band impedance transformer by utilizing stubbed coupling line for matching a load at three arbitrary frequencies is proposed. The transformer is composed of two parts, and each part is constructed from parallel-coupled transmission lines. Two structures with different configurations of the proposed transformer have been given and analyzed. Then, the close-form equat...

2001
T. G. Engel

The analysis, design, and operation of high-voltage, transformer-coupled LC vector inversion generators are presented and discussed. The transformer-coupled LC inversion generator is easy to construct and, compared with Marx-type generators and conventional LC vector inversion generators, requires only one inversion switch, independent of the number of voltage multiplication stages. The transfo...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید