نتایج جستجو برای: artisan iol

تعداد نتایج: 2687  

Journal: :Journal of dairy science 2014
Andrea Bouma Catherine A Durham Lisbeth Meunier-Goddik

Lack of valid economic data for artisan cheese making is a serious impediment to developing a realistic business plan and obtaining financing. The objective of this study was to determine approximate start-up and operating costs for an artisan cheese company. In addition, values are provided for the required size of processing and aging facilities associated with specific production volumes. Fo...

Journal: :American journal of ophthalmology 2003
Jose L Güell Mercedes Vázquez Francoise Malecaze Felicidad Manero Oscar Gris Fortino Velasco Helene Hulin Jaune Pujol

PURPOSE To evaluate efficacy, predictability, and safety of Artisan toric phakic intraocular lens (Ophtec, Groningen, The Netherlands) implantation for the correction of astigmatism higher than 2 diopters. DESIGN Interventional case series. METHODS This prospective study included 27 eyes of 16 patients with a mean preoperative spherical equivalent of -11.78 +/- 6.24 diopters and a mean preo...

2008
Rinaldo Cervellati Emanuela Greco Stefano Costa Maria Clelia Guerra Ester Speroni

The antioxidant capacities and the total phenolic content in cocoa liquor directly manufactured chocolate from an artisan manufacturer were measured using different in vitro methods (BR, TEAC, and Folin– Ciocalteu Reagent). These parameters were then compared with those of a chocolate made by a leading manufacturing company producing chocolate and cocoa-containing products. A statistical analys...

2009
Dave Richards

Dave Richards Artisan Software Tools Suite 701, Eagle Tower Montpelier Drive Cheltenham, UK, GL50 1TA [email protected] Andrew Stuart Westinghouse Rail Systems Ltd PO Box 79 Pew Hill, Langley Park Chippenham, Wiltshire, SN15 1JD, UK [email protected] Matthew Hause Artisan Software Tools Suite 701, Eagle Tower Montpelier Drive Cheltenham, UK, GL50 1TA Matthew.Hause@arti...

Journal: :Journal of Plasma Physics 2022

The gap between a recently developed dynamical version of relaxed magnetohydrodynamics (RxMHD) and ideal MHD (IMHD) is bridged by approximating the zero-resistivity "Ideal" Ohm's Law (IOL) constraint using an augmented Lagrangian method borrowed from optimization theory. augmentation combines pointwise vector Lagrange multiplier global penalty function can be used either for iterative enforceme...

1999
V. Broz O. Carmichael S. Thayer M. Hebert J. Osborn

Integration of three-dimensional textured scene mapping and object recognition presents many opportunities for assisted automation. We present Artisan, a software package that synthesizes these elements to form a user-friendly whole. Artisan uses a variety of 3D sensors, including laser range scanners and stereo systems, to acquire both image and range data. Artisan automatically finds the tran...

Journal: :بینا 0
فرید کریمیان f karimian ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranدانشگاه علوم پزشکی شهید بهشتی علیرضا برادران رفیعی a baradaran rafii ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranدانشگاه علوم پزشکی شهید بهشتی جواد هاشمیان j hashemian tehran university of medical sciences, tehran, iranدانشگاه علوم پزشکی تهران علی هاشملو a hashemloo ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranدانشگاه علوم پزشکی شهید بهشتی ابراهیم جعفری e jafari tehran university of medical sciences, tehran, iranدانشگاه علوم پزشکی تهران مهدی یاسری m yaseri ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranگروه بهداشت و آمار حیاتی- دانشگاه علوم پزشکی تهران

purpose: to compare visual outcomes and surgical complications of three phakic intraocular lenses (piols); artisan, artiflex and the implantable collamer lens (icl) for correction of moderate to high myopia. methods: in this historical cohort study, 112 myopic eyes that were operated between 2005 and 2010 and implanted with one of these three piols were evaluated (artisan 40 eyes, artiflex 36 e...

2008
Seung Mo Kim Sangkyung Choi

PURPOSE To evaluate the clinical efficacy and complications of intraocular lens (IOL) exchange. METHODS A review of medical records was performed for 52 eyes that had undergone an IOL exchange due to IOL opacification. Surgical complications and their incidences were analyzed. The mean best corrected visual acuity (BCVA) after the IOL exchange was compared with the mean pre-exchange BCVA and ...

Journal: :Journal of cataract and refractive surgery 2005
Robert A Latkany Amit R Chokshi Mark G Speaker Jodi Abramson Barrie D Soloway Guopei Yu

PURPOSE To evaluate the effect of refractive surgery on intraocular lens (IOL) power calculation, compare methods of IOL power calculation after refractive surgery, evaluate the effect of pre-refractive surgery refractive error on IOL deviation, review the literature on determining IOL power after refractive surgery, and introduce a formula for IOL calculation for use after refractive surgery f...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید