نتایج جستجو برای: tg 43 dosimetric parameters

تعداد نتایج: 690233  

Journal: :Medical physics 2011
Larry A DeWerd Geoffrey S Ibbott Ali S Meigooni Michael G Mitch Mark J Rivard Kurt E Stump Bruce R Thomadsen Jack L M Venselaar

This report addresses uncertainties pertaining to brachytherapy single-source dosimetry preceding clinical use. The International Organization for Standardization (ISO) Guide to the Expression of Uncertainty in Measurement (GUM) and the National Institute of Standards and Technology (NIST) Technical Note 1297 are taken as reference standards for uncertainty formalism. Uncertainties in using det...

2015
Delaram Pakravan Mahdi Ghorbani Ali Soleimani Meigooni

PURPOSE Recently a number of hypothetical sources have been proposed and evaluated for use in brachytherapy. In the present study, a hypothetical (101)Rh source with mean photon energy of 121.5 keV and half-life of 3.3 years, has been evaluated as an alternative to the existing high-dose-rate (HDR) sources. Dosimetric characteristics of this source model have been determined following the recom...

Arjang Shahvar Gholamreza Raisali, Mahdi Sadeghi, Maryam Ghasemi Ghonchehnazi Vahideh Ataeinia

Introduction: The use of low energy isotopes such as  103 Pd in brachytherapy for the treatment of cancers  such as prostate, eye, head, neck, breast and cervix is increasing. In this regard, different models of Pd- 103  seeds  have  been  designed  and  manufactured  at  the  Agricultural,  Medical  and  Industrial  Research  School (AMIRS) of Atomic Energy Organization of Iran. In this resear...

Journal: :iranian journal of radiation research 0
o. kiavar department nuclear engineering, science and research branch, islamic azad university, tehran, iran m. sadeghi agricultural, medical & industrial research school, nuclear science and technology research institute, karaj, iran

background: recently, different investigators have studied the possibility of radiation therapy in restenosis prevention and have shown promising results. in this study a unique radioactive source for intra vascular brachytherapy (ivbt) was investigated. the two-dimensional dose distribution in water for a 32p ivbt stent has been calculated. the pure beta emitter source 32p has been coated on p...

2008
Shahid B. Awan Sharifeh A. Dini Manzoor Hussain David Soleimani‐Meigooni Ali S. Meigooni

In 2001, the use of cylindrical coordinates was demonstrated to be more suitable than was the use of polar coordinates for accurate computer calculations during treatment planning for 192Ir intravascular brachytherapy sources. In the present work, we investigated the applicability of cylindrical coordinate-based TG-43U1 parameters for dosimetric evaluation and dose calculations for RadioCoil 10...

2015
Christian N. Valdés Gustavo H. Píriz Enrrique Lozano

The aim of this work is to evaluate the performance of a commercial brachytherapy treatment planning system (TPS) with TG-43 Vendors Input Data (VID), analyze possible discrepancies with respect to a proper reference source and its implications for standard treatments, and judge the effectiveness of certain widespread recommended quality controls to find potential errors related with the interp...

Journal: :journal of biomedical physics and engineering 0
z. naghshnezhad department of medical radiation engineering, shiraz university, shiraz, iran r. faghihi department of medical radiation engineering, shiraz university, shiraz, iran m. a. mosleh-shirazi center for research in medical physics and biomedical engineering, and department of radiotherapy, shiraz university of medical sciences, shiraz, iran a. s. meigooni comprehensive cancer center of nevada, 3730 s. eastern dr., las vegas, nv, usa

background: the patterson-parker table was created in 1934 to determine mg-hr required to deliver the prescribed dose to the treatment area. these tables were created using the dosimetric data for 226ra that was determined in air and were utilized for dose calculations around implants with ra-equivalent radionuclides such as 137cs and 192ir. therefore, the differences of the tissue attenuation ...

Journal: :Computers in Biology and Medicine 2021

Accurate calculation of the absorbed dose delivered to tumor and normal tissues improves treatment gain factor, which is major advantage brachytherapy over external radiation therapy. To address simplifications TG-43 assumptions that ignore dosimetric impact medium heterogeneities, we proposed a deep learning (DL)-based approach, accuracy while requiring reasonable computation time. We develope...

A.A. Mowlavi, M. Yazdani,

Background: Monte Carlo determination of TG-43 brachytherapy dosimetry parameters and dose distribution calculation for 131Cs source model CS-1 are presented in this study. Materials and Methods: The dose distribution was calculated around the 131Cs Model CS-1 located in the center of 30 cm ×30 cm ×30 cm water, and soft tissue phantoms cube using MCNP code by Monte Carlo method. The percentage ...

M. Sadeghi, O. Kiavar,

Background: Recently, different investigators have studied the possibility of radiation therapy in restenosis prevention and have shown promising results. In this study a unique radioactive source for intra vascular brachytherapy (IVBT) was investigated. The two-dimensional dose distribution in water for a 32P IVBT stent has been calculated. The pure beta emitter source 32P has been co...