نتایج جستجو برای: inclined cantilever

تعداد نتایج: 15881  

2013
Vineet Tiwari Geetika Srivastava

Piezoelectric cantilevers have been in great demand in sensor and actuator applications. The tip displacement of the cantilever is the most important and sensitive parameter in the actuation mode. Hence, in this study a bimorph cantilever beam has been chosen as the element of study consisting of two active piezoelectric layers of PVDF bonded together. An attempt has been made to establish the ...

Journal: :Microscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada 2007
Natalia Nugaeva Karin Y Gfeller Natalia Backmann Marcel Düggelin Hans Peter Lang Hans-Joachim Güntherodt Martin Hegner

We demonstrate a new sensitive biosensor for detection of vital fungal spores of Aspergillus niger. The biosensor is based on silicon microfabricated cantilever arrays operated in dynamic mode. The change in resonance frequency of the sensor is a function of mass binding to the cantilever surface. For specific A. niger spore immobilization on the cantilever, each cantilever was individually coa...

2007
K. J. Kim K. Park J. Lee Z. M. Zhang W. P. King

This paper reports quantitative topographical measurements using a heated atomic force microscope (AFM) cantilever probe. The study compares opographies measured by the cantilever thermal signal to topographies measured by the laser-deflection signal of an AFM system. The experiment sed 20 and 100 nm tall Si gratings as topographical test samples. The cantilever heater temperature ranged from 1...

Journal: :I. J. Robotics Res. 2010
Qi Wang Vincent Hayward

This paper presents a tactile transducer device that is optimized from biomechanical data and has a compact, yet modular design. The tactile transducer comprises a 6 × 10 piezo bimorph actuator array with a spatial resolution of 1.8 × 1.2 millimeters and a wide temporal bandwidth. The actuator mounting method was improved from a conventional cantilever method to a dual-pinned method, giving the...

Journal: :Ultramicroscopy 2008
M H Mahdavi A Farshidianfar M Tahani S Mahdavi H Dalir

This paper focuses on the development of a complete model of an atomic force microscope (AFM) micro-cantilever beam, based on considering the effects of four major factors in modeling the cantilever. They are: rotary inertia and shear deformation of the beam and mass and rotary inertia of the tip. A method based on distributed-parameter modeling approach is proposed to solve the governing equat...

Journal: :Acta odontologica latinoamericana : AOL 2014
Rafaella M O Cid Kyle Stanley Ernesto B Cordero Cesar A M Benfatti Marco A Bianchini

This study selected forty-two implants with full arch implantsupported fixed prostheses (with and without a cantilever) with at least five years' loading. Radiographic measurements were performed using Digimizer software (MedCalc Software, Belgium). Bone loss was measured on the distal side of the implant, from the surface of the platform to the edge of the bone crest, and the extent of the can...

Journal: :international journal of nano dimension 0
a. s. kurhekar department of electrical engineering, indian institute of technology bombay, powai, mumbai 400 076. india. p. r. apte department of electrical engineering, indian institute of technology bombay, powai, mumbai 400 076. india.

one of the bio-sensing mechanisms is mechanical. rather than measuring shift in resonance frequency, we adopt to measure the change in spring constant due to adsorption, as one of the fundamental sensing mechanism. this study explains  determination of spring constant of a surface functionalized micro machined micro cantilever, which resonates in a trapezoidal cavity-on silicon wafer, with the ...

2008
J. W. van Honschoten W. W. Koelmans S. M. Konings L. Abelmann M. Elwenspoek

We present a novel ultrasensitive magnetometry technique using a micromachined magnetic cantilever that is brought in resonance. The induced magnetic moment generates a torque on the cantilever, thereby effectively stiffening the cantilever spring constant and changing its resonance frequency. Experiments are in good correspondence with the presented analytical model for this frequency shift, p...

2004
Murti V. Salapaka J. Chen

In this paper, the most widely used mode of atomic force microscopy imaging where the cantilever is oscillated at its resonant frequency is studied. It is shown that the amplitude and the sine of the phase of the orbit vary linearly with respect to the cantilever-sample distance. Experiments conducted on a silicon cantilever agree with the theory developed.

1997
Andrew C. Hillier Allen J. Bard

An ac imaging mode for atomic force microscopy ~AFM! has been developed that employs a thermally driven bimetallic cantilever to sense surface topography. Oscillations are induced in a composite cantilever, comprising a Si3N4 layer and Au overcoat, by local heating with a resistive wire heater placed in close proximity to the cantilever. Cantilever bending occurs upon heating due to the differe...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید