نتایج جستجو برای: finite element gafchromic film

تعداد نتایج: 481855  

Journal: :Physics in medicine and biology 2004
Martin J Butson Tsang Cheung Peter K N Yu

The visible absorption spectra of Gafchromic XR type-T radiochromic film have been investigated to analyse the dosimetry characteristics of the film with visible light densitometers. Common densitometers can use photospectrometry, fluorescent light (broad-band visible), helium neon (632 nm), light emitting diode (LED) or other specific bandwidth spectra. The visible absorption spectra of this f...

Journal: :Physics in medicine and biology 2002
Martin J Butson Peter K N Yu Tsang Cheung Peter Metcalfe

This short note investigates the dose characteristics of a relatively new high sensitivity radiochromic film (Gafchromic HS) and compares dose and energy response to various Gafchromic film types and radiographic (EDR-2) film. The original MD-55-1 and two improved sensitivity films, MD-55-2 and HS film, were investigated for energy and dose response. Results show that the energy response of the...

Journal: :Physics in medicine and biology 2014
A Subiel V Moskvin G H Welsh S Cipiccia D Reboredo P Evans M Partridge C DesRosiers M P Anania A Cianchi A Mostacci E Chiadroni D Di Giovenale F Villa R Pompili M Ferrario M Belleveglia G Di Pirro G Gatti C Vaccarezza B Seitz R C Isaac E Brunetti S M Wiggins B Ersfeld M R Islam M S Mendonca A Sorensen M Boyd D A Jaroszynski

Very high energy electrons (VHEE) in the range from 100-250 MeV have the potential of becoming an alternative modality in radiotherapy because of their improved dosimetry properties compared with MV photons from contemporary medical linear accelerators. Due to the need for accurate dosimetry of small field size VHEE beams we have performed dose measurements using EBT2 Gafchromic® film. Calibrat...

2015
Hong-Wei Liu James Gräfe Rao Khan Ivo Olivotto J Eduardo Villarreal Barajas

PURPOSE To evaluate the role of in vivo dosimetry with radiochromic films for dose verification in cutaneous radiation therapy (RT). METHODS Five patients with 8 cutaneous or sub-cutaneous malignancies of the face, neck, trunk and extremity receiving RT were included. Orthovoltage, megavoltage photon therapies were applied based on anatomic location. The delivered dose for each target was mea...

2007
Martina Fuss Eva Sturtewagen Carlos De Wagter Dietmar Georg

The suitability of radiochromic EBT film was studied for high-precision clinical quality assurance (QA) by identifying the dose response for a wide range of irradiation parameters typically modified in highly-conformal treatment techniques. In addition, uncertainties associated with varying irradiation conditions were determined. EBT can be used for dose assessment of absorbed dose levels as we...

2017
Grzegorz Zwierzchowski Grzegorz Bieleda Janusz Skowronek

Background Fast and easily repeatable methods for commissioning procedures for brachytherapy (BT) treatment planning systems (TPS) are needed. Radiochromic film dosimetry with gamma analysis is widely used in external beam quality assurance (QA) procedures and planar film dosimetry is also increasingly used for verification of the dose distribution in BT applications. Using the gamma analysis m...

2016
Sandra Sarmento Joana Pereira Maria José Sousa Luís Cunha Anabela G. Dias Miguel F. Pereira Augusto D. Oliveira João V. Cardoso Luís M. Santos Margarida Gouvêa Joana Lencart João G. Alves João A.M. Santos

Computed tomography fluoroscopy (CTF) is a useful imaging technique to guide biopsies, particularly lung biopsies, but it also has the potential for very high hand exposures, despite use of quick-check method and needle holders whenever feasible. Therefore, reliable monitoring is crucial to ensure the safe use of CTF. This is a challenge, because ring dosimeters monitor exposure only at the bas...

In the current study, the effects of Casimir force and squeeze film damping on pull-in instability and dynamic behavior of electrostatically actuated nano and micro electromechanical systems are investigated separately. Linear elastic membrane theory is used to model the static and dynamic behavior of the system for strip, annular and disk geometries. Squeeze film damping is modeled using nonli...

Journal: :Medical physics 2005
Alexandra Rink I Alex Vitkin David A Jaffray

A new radiochromic film, GafChromic EBT, was investigated for use in a real-time radiation dosimetry system. It was found to be approximately eight times more sensitive to ionizing radiation dose, exhibited less postexposure development and achieved stable readout faster than one of its predecessors, GafChromic MD-55. A clear distinction in change in optical density between exposure and postexp...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید