نتایج جستجو برای: biocompatibility testing

تعداد نتایج: 346246  

Journal: :Archives of ophthalmology 2005
David T L Liu Chi-Lai Li Vincent Y W Lee Dennis S C Lam

OBJECTIVE To develop an intraocular vision aid to provide artificial vision in severely traumatized eyes, where neuroretinal function could be preserved but irreversible anterior segment opacification resulted in blindness. METHODS The basis of an intraocular vision aid is in principle a telemetric circuit to bridge the opaque cornea and to allow for artificial light stimulation of the retina...

Journal: :Acta biomaterialia 2012
E L McGinley G P Moran G J P Fleming

Nickel-chromium (Ni-Cr) alloys used in fixed prosthodontics have been associated with type IV Ni-induced hypersensitivity. We hypothesised that the full-thickness human-derived oral mucosa model employed for biocompatibility testing of base-metal dental alloys would provide insights into the mechanisms of Ni-induced toxicity. Primary oral keratinocytes and gingival fibroblasts were seeded onto ...

Journal: :Transactions of the American Ophthalmological Society 2003
Daniel M Schwartz

PURPOSE First, to determine whether a silicone light-adjustable intraocular lens (IOL) can be fabricated and adjusted precisely with a light delivery device (LDD). Second, to determine the biocompatibility of an adjustable IOL and whether the lens can be adjusted precisely in vivo. METHODS After fabrication of a light-adjustable silicone formulation, IOLs were made and tested in vitro for cyt...

Journal: :Journal of glaucoma 2015
Ian Grierson Hady Saheb Malik Y Kahook Murray A Johnstone Iqbal I K Ahmed Andrew T Schieber Carol B Toris

PURPOSE To assess the biocompatibility of a novel implant made of Nitinol (nickel-titanium alloy), designed to improve aqueous humor outflow. MATERIALS AND METHODS In the first arm of biocompatibility testing, microstents were surgically inserted into Schlemm's canal (SC) of 2 non-human primates (NHPs), and a third NHP served as a surgical sham control. After 13 weeks the animals were killed,...

Journal: :ACS applied materials & interfaces 2014
Rok Podlipec Selestina Gorgieva Darija Jurašin Iztok Urbančič Vanja Kokol Janez Strancar

Understanding biocompatibility of materials and scaffolds is one of the main challenges in the field of tissue engineering and regeneration. The complex nature of cell-biomaterial interaction requires extensive preclinical functionality testing by studying specific cell responses to different biomaterial properties, from morphology and mechanics to surface characteristics at the molecular level...

Journal: :Journal of materials science. Materials in medicine 2011
Daniel Eberli Anthony Atala James J Yoo

To determine whether the use of multiple layers of acellular bladder matrix (ABM) is more suitable for the treatment of abdominal wall hernia than a single layered ABM. The feasibility, biocompatibility and mechanical properties of both materials were assessed and compared. Biocompatibility testing was performed on 4 and 1 layered ABM. The matrices were used to repair an abdominal hernia model ...

Journal: Nanomedicine Journal 2013

Aligned and random nanocomposite nanofibrous scaffolds were electrospun from polycaprolactone (PCL), poly (vinyl alcohol) (PVA) and hydroxyapatite nanoparticles (nHA). The morphology and mechanical characteristics of the nanofibers were evaluated using scanning electron microscopy and tensile testing, respectively. Scanning electron microscopy revealed fibers with an average diameter of 123 ± 3...

2016
Aleksandra Čairović Vesna Maksimović Katarina Radović Slobodan Djurišić

Aleksandra ČAIROVIĆ Faculty of Dental Medicine University of Belgrade Clinic for Prosthodontics Rankeova 4, 11000 Belgrade Serbia [email protected] SUMMARY Introduction Increases in market prices of gold over the last 20 years have led to expansion of basic dental alloys, which, primarily due to their good mechanical properties and acceptable prices, have found their place in everyday...

2015
Julia Matena Svea Petersen Matthias Gieseke Michael Teske Martin Beyerbach Andreas Kampmann Hugo Murua Escobar Nils-Claudius Gellrich Heinz Haferkamp Ingo Nolte Alexander M. Seifalian

Degradable implant material for bone remodeling that corresponds to the physiological stability of bone has still not been developed. Promising degradable materials with good mechanical properties are magnesium and magnesium alloys. However, excessive gas production due to corrosion can lower the biocompatibility. In the present study we used the polymer coating polycaprolactone (PCL), intended...

Journal: :Materials science & engineering. C, Materials for biological applications 2017
C H Lin C H Chen Y S Huang C H Huang J C Huang J S C Jang Y S Lin

The Ti/Zr-based metallic glasses (MGs) with various Cu contents are prepared, with nominal compositions of Ti45Zr40Si15 (Cu-free), Ti45Zr40Si10Cu5 (low-Cu), and Ti45Zr20Cu35 (high-Cu). The mechanical properties, corrosion resistance, and in-vitro biocompatibility of these MGs are investigated by means of nano-indentation, electrochemical analyses, MTS assays and inductively coupled plasma mass ...

نمودار تعداد نتایج جستجو در هر سال