جواد رحیقی, حسین قدس, شهرزاد شیوخی مرتضی جعفرزاده خطیبانی

پایداری نور خروجی، قدرت تفکیک انرژی و بازده سوسوزنی در طیف‌نگاری پرتو گاما از اهمیت زیادی برخوردار است. با توجه به تغییرات دمای ناشی از شرایط اندازه‌گیری و تأثیر آن بر تابع پاسخ سوسوزن‌های یدور سدیم NaI(Tl) و اکسید ژرمنات بیسموت BGO، به بررسی اثر دما بر سوسوزن‌های یدور سدیم NaI(Tl) و اکسید ژرمنات بیسموت BGO در محدوده‌ی نسبتاً وسیعی از دما پرداخته شده است. اندازه‌گیری‌ها روی کریستال‌هایی با ابعاد...

Journal: :Crystals 2022

The aim of this study is to evaluate the suitability crystalline scintillator LaCl3:Ce for possible use in hybrid medical imaging systems, such as PET/CT and SPECT/CT scanners. For purpose, a single crystal (10 × 10 mm3) was irradiated by X-rays within tube voltage range from 50 150 kVp, absolute efficiency (AE) measured experimentally. energy absorption (EAE), quantum detection (QDE), spectral...

Journal: :Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 1994

1996
K. I. Hahn C. R. Brune R. W. Kavanagh W. K. Kellogg

Angular distributions of the 14–17 MeV g rays from the Li~p ,g) reaction at Ep5450, 402, and 80 keV were measured at 0°<u lab<135°, using a BGO detector and a 28-mg/cm 2 LiF target. The angular distributions at Ep5450 and 402 keV agree with the previous results by Mainsbridge; at Ep580 keV the ground-state transition is anisotropic on the order of 20%, confirming recent results by Chasteler et al.

2006
Arman Rahmim Richard L. Wahl

This article is intended to provide an overview of various aspects of clinical PET/CT. These include discussions of: (i) Important areas of clinical application; (ii) Opportunities in clinical research; (iii) Scanner and operating-mode considerations (e.g. BGO vs. LSO, LYSO or GSO scanners, 2D vs. 3D imaging). (iv) Study-specific considerations (e.g. patient preparation and positioning issues, ...

Journal: :iranian journal of nuclear medicine 2009
parham geramifar mohammad reza ay mojtaba shamsaie zafarghandi george loudos arman rahmim

combined pet/ct scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. as the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner performances on an objective ...

Arman Rahmim George Loudos Mohammad Reza Ay Mojtaba Shamsaie Zafarghandi Parham Geramifar,

  Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...

Journal: :Stroke 1981
A H Lockwood P J Kenny

This report describes the construction and performance characteristics of a device capable of making rapid serial measurement of rat brain radioactivity following the administration of a positron emitting isotope. Two bismuth germanate oxide (BGO) scintillation detectors in a coincidence detection circuit are used to achieve the necessary degree of collimation. Data from the device can be used ...

Journal: :IEEE transactions on radiation and plasma medical sciences 2021

Bismuth germanate (BGO) was the preferred crystal for positron emission tomography (PET) scanners, but substituted with emergence of faster crystals. Improvements in silicon photomultipliers (SiPMs) and use fast high frequency readout make it possible to prompt Cherenkov BGO order boost achievable coincidence time resolution (CTR) significantly. The large fluctuations detected photon yield are ...