نتایج جستجو برای: air kerma strength
تعداد نتایج: 408460 فیلتر نتایج به سال:
A vacuum-sealed miniature X-ray tube based on a carbon nanotube field-emission electron source has been demonstrated. The diameter of the X-ray tube is 10 mm; the total length of the tube is 50 mm, and no external vacuum pump is required for the operation. The maximum tube voltage reaches up to 70 kV, and the X-ray tube generates intense X-rays with the air kerma strength of 108 Gy·cm2 min-1. I...
A comparison has been made of the air-kerma standards for medium-energy x-rays of the National Institute of Standards and Technology (NIST) and the Bureau International des Poids et Mesures (BIPM). The comparison involved a series of measurements at the BIPM and the NIST using the air-kerma standards and three NIST reference-class transfer ionization chamber standards. Reference beam qualities ...
The primary standard for air kerma for the gamma radiation of Cs-137, of the Metrological Laboratory of Ionising Radiation (LMRI), is an ionisation chamber of the type CC01. This instrument was, for the first time, used to characterize the radiation field, in terms of air kerma, produced by a Cs-137 source in an irradiator Shepherd model 81, used mainly for radiation protection calibration purp...
PURPOSE This study was carried out to assess the radiation dose to patients undergoing interventional radiology procedures at Ramathibodi Hospital, Bangkok, Thailand. METHODS Data were collected from 60 patients under transarterial oily-chemoembolisation (TOCE) and femoral angiography performed with the Toshiba Infinix model VC-i FPD single plane system. Data were also collected from 60 patie...
PURPOSE Recently a number of hypothetical sources have been proposed and evaluated for use in brachytherapy. In the present study, a hypothetical (101)Rh source with mean photon energy of 121.5 keV and half-life of 3.3 years, has been evaluated as an alternative to the existing high-dose-rate (HDR) sources. Dosimetric characteristics of this source model have been determined following the recom...
In recent times, ionizing radiation has been used around the world to screen persons for non-medical purposes, namely to detect bulk explosives or other contraband hidden on the body including materials not registered by metal detectors. In contrast to conventional transmission or projection imaging, backscatter and forward-scatter systems employ a "flying spot" of x rays and large-area detecto...
Various radiation detectors including electronic personal emergency radiation detectors (PERDs), radiochromic film cards and thermoluminescent dosimeters (TLDs) were used to validate a subset of the radiological test requirements listed in the American National Standards Institute/The Institute of Electrical and Electronic Engineers (ANSI/IEEE) N42.49 standard. The subset of tests included the ...
The attenuating properties of several types of lead (Pb)-based and non-Pb radiation shielding materials were studied and a correlation was made of radiation attenuation, materials properties, calculated spectra and ambient dose equivalent. Utilizing the well-characterized x-ray and gamma ray beams at the National Research Council of Canada, air kerma measurements were used to compare a variety ...
Modern fluoroscopes used for image-based guidance in interventional procedures are complex X-ray machines, with advanced image acquisition and processing systems capable of automatically controlling numerous parameters based on defined protocol settings. This study evaluated and compared approaches to technique factor modulation and air kerma rates in response to simulated patient thickness var...
PURPOSE Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with specialized conical applicators placed directly on the lesion. Applicators are available for use with high dose rate (HDR)(192)Ir sources, as w...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید