rotection schemes employing the differential relaying principle exhibit certain limitations in applications with power transformers. This is because the detection of a differential current does not clearly distinquish between internal faults and other possible conditions. Among the phenomena most likely to upset the current balance and cause the relay to malfunction are inrush magnetizing curre...
power system overvoltages due to switching, lightning and other disturbances are the main problem for designers of the power transformers. once some frequencies of the incoming surges match with some of the natural frequencies of transformer winding, the resonance phenomenon is expected in transformer winding. the resonant overvoltages may destroy the insulation between turns and cause to insul...
This paper presents an improvement of digital differential relay reliability for protecting a large power transfer is discussed. First, the Fourier sine and cosine coefficients required for fundamental, second third and fifth harmonies determination have been calculated using rectangular transfer technique. Then, these harmonics have been used in harmonics restrain and blocking techniques used ...
For the current transformers (CTs) on the delta side measure the line current instead of the phase current, line current differential protection is adopted in transformers connected in wye-delta mode currently. However, the symmetry feature of inrush current in line current differential protection may invalidate the inrush current restrained criterion. A calculating method of current through de...
Intriguing mal-operations and fail-to-trip of the differential protection of the converter transformer in the HVDC system are reported. In this paper, the mechanism of these abnormal operation behaviors is analyzed. By virtue of deliberately designed models of the converter transformer and the HVDC transmission system, a variety of simulation tests are carried out and above mentioned strange op...
The aim of this paper is to extend a hybrid protection plan for Power Transformer (PT) based on MRA-KSIR-SSVM. This paper offers a new scheme for protection of power transformers to distinguish internal faults from inrush currents. Some significant characteristics of differential currents in the real PT operating circumstances are extracted. In this paper, Multi Resolution Analysis (MRA) is use...
The reliability of the transformer differential protection is under threat from multiple interferences, including inrush condition, current saturation and arc fault condition. For improvement, a new method proposed to discriminate conditions other non-fault conditions. Firstly, identifies unidirectional via index, since only it exhibits characteristic. Then, remaining signals are classified by ...
With the evolution of Process Bus (IEC 61850-9-2), there is a need to assess the performance of protection schemes using process bus against those where traditional copper wires are implemented. Differential protection is the fundamental and most commonly used protection for transformers, motors and generators. In this paper a power system is modelled in SimPowerSystems and is executed in real-...