نتایج جستجو برای: tg 43 dosimetric parameters
تعداد نتایج: 690233 فیلتر نتایج به سال:
The purpose of this study is to determine the dosimetric parameters of a new 125I brachytherapy seed model, using Monte Carlo (MC) simulations according to the TG-43U1 recommendation. The Monte Carlo simulated dosimetric parameters of this sourse have been provided with MCNPX v.2.6 code. The source contains a cylindrical Ag+Al2O3 marker which is located at the center of the seed and onto which...
The TG-43 recommended dosimetric characteristics of a new 125I brachytherapy source have been experimentally and theoretically determined. The measurements were performed in Solid Water using LiF TLDs. The calculations were performed using Monte Carlo simulations in Solid Water and water. The measured data were compared with calculated values as well as the reported data in literature for other...
Monte Carlo calculations and TLD measurements have been performed for the purpose of characterizing dosimetric properties of new commercially available brachytherapy sources. All sources tested consisted of a solid core, upon which a thin layer of 125I has been adsorbed, encased within a titanium housing. The PharmaSeed BT-125 source manufactured by Syncor is available in silver or palladium co...
PURPOSE Brachytherapy treatment has been a cornerstone for management of various cancer sites, particularly for the treatment of gynecological malignancies. In low dose rate brachytherapy treatments, 137Cs sources have been used for several decades. A new 137Cs source design has been introduced (model 67-6520, source B3-561) by Isotope Products Laboratories (IPL) for clinical application. The g...
introduction: the use of low energy isotopes such as 103 pd in brachytherapy for the treatment of cancers such as prostate, eye, head, neck, breast and cervix is increasing. in this regard, different models of pd- 103 seeds have been designed and manufactured at the agricultural, medical and industrial research school (amirs) of atomic energy organization of iran. in this resear...
background: monte carlo determination of tg-43 brachytherapy dosimetry parameters and dose distribution calculation for 131cs source model cs-1 are presented in this study. materials and methods: the dose distribution was calculated around the 131cs model cs-1 located in the center of 30 cm ×30 cm ×30 cm water, and soft tissue phantoms cube using mcnp code by monte carlo method. the percentage ...
Introduction: 103Pd is a low energy source, which is used in brachytherapy. According to the standards of American Association of Physicists in Medicine, dosimetric parameters determination of brachytherapy sources before the clinical application was considered significantly important. Therfore, the present study aimed to compare the dosimetric parameters of the target source using the water ph...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید