نتایج جستجو برای: tear film

تعداد نتایج: 100290  

2014
Maciej M. Bartuzel Dorota H. Szczesna-Iskander D. Robert Iskander

An image processing algorithm is developed for quantitative assessment of tear meniscus dynamics from continuous optical coherence tomography (OCT) measurements. Clinical utility of dynamic OCT tear meniscus measurement is assessed in studies of tear meniscus parameters. The results indicate that any apparent changes in the early post-blink phase meniscus parameters are essentially related to t...

Journal: :iranian journal of radiation research 0
g.k. gedik selcuk university medical faculty, department of nuclear medicine, konya, turkey s. gedik selcuk university medical faculty, department of ophthalmology, konya, turkey b.e. koktekir selcuk university medical faculty, department of ophthalmology, konya, turkey l. kebapcilar selcuk university medical faculty, department of endocrinology, konya, turkey p.o. kara mersin university faculty of medicine, department of nuclear medicine, mersin, turkey

background: the therapeutic administration of 131i for thyroid remnant ablation and for metastases comes up with some adverse effects. this study was conducted to investigate whether single high dose radioiodine therapy affects lacrimal gland functions or not. materials and methods: seventy-eight eyes of 39 patients, who were diagnosed as differentiated thyroid carcinoma, were objectively teste...

Journal: :Arquivos brasileiros de oftalmologia 2017
Goktug Demirci Sevil Karaman Erdur Rukiye Aydin Ali Balevi Mustafa Eliacik Mustafa Ozsutcu Oktay Olmuscelik

Purpose: The aim of this study was to evaluate tear osmolarity, tear film function, and ocular surface changes in patients with psoriasis. Methods: At a single center, 30 eyes of 30 patients with psoriasis (group 1) and 30 eyes of 30 healthy individuals (group 2) were evaluated using the Ocular Surface Disease Index (OSDI) questionnaire, Schirmer I test, tear film break-up time (TBUT) test, s...

2013
Amber L. Labelle

The primary function of the lacrimal system is to produce and drain the tear film from the surface of the eye. The tear film is composed of three integrated layers: the aqueous, mucus, and lipid layers. The aqueous layer is produced by the orbital lacrimal gland and gland of the third eyelid and secreted onto the ocular surface through ductules that traverse the conjunctiva. The mucus layer is ...

Journal: :Investigative ophthalmology & visual science 1997
H B Chen S Yamabayashi B Ou Y Tanaka S Ohno S Tsukahara

PURPOSE To visualize the in vivo structure and to investigate the composition of rat precorneal tear film. METHODS An in vivo cryofixation with freeze substitution method of electron microscopy was used for the study. For light and transmission electron microscopy, a small amount of aluminum powder was used as a tracer spread on the corneal surface. The eyeballs were immediately and quickly f...

2015
Kumar Ramesh Inderjit Kaur Prempal Kaur

Objective(s): Evaluate the effect of topical antiglaucoma drugs on tear film and determine the time taken to develop symptoms and or signs of dry eye in diagnosed open angle glaucoma patients by Schirmer's test I, Schirmer's test II, Tear film break up time. Method(s): This prospective study was carried out in 60 patients attending Ophthalmology outdoor with newly diagnosed patients of primary ...

Journal: :Annals of anatomy = Anatomischer Anzeiger : official organ of the Anatomische Gesellschaft 2017
Agnieszka Olżyńska Lukasz Cwiklik

Tear film lipid layer is a complex lipid mixture forming the outermost interface between eye and environment. Its key characteristics, such as surface tension and structural stability, are governed by the presence of polar lipids. The origin of these lipids and exact composition of the mixture are still elusive. We focus on two minor polar lipid components of the tear film lipid later: sphingom...

Journal: :Experimental Eye Research 2013

2010
R. J. Braun P. E. King-Smith

The tear film on the front of the eye is critical to proper eyesight; in many mathematical models of the tear film, the tear film is assumed to be on a flat substrate. We re-examine this assumption by studying the effect of a substrate which is representative of the human cornea. We study the flow of a thin fluid film on a prolate spheroid which is a good approximation to the shape of the human...

Journal: :Investigative ophthalmology & visual science 2018
Takashi Itokawa Yukinobu Okajima Takashi Suzuki Koji Kakisu Hiroko Iwashita Yoshitaka Murakami Yuichi Hori

Purpose To investigate the correlation between the changes in the ocular surface temperature (OST) and tear film stability over soft contact lenses (SCLs). Methods We enrolled 20 eyes of 20 normal SCL wearers (20 men; 24.4 ± 4.1 years). We used four different daily disposable SCLs: one silicone hydrogel lens (delefilcon A) and three hydrogel lenses (etafilcon A with polyvinylpyrrolidone [PVP]...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید