نتایج جستجو برای: seismic isolation systems
تعداد نتایج: 1336582 فیلتر نتایج به سال:
Received: December 19, 2016 Revised: February 06, 2017 Accepted: March 20, 2017 Abstract: Introduction: Seismic isolation has been proven to be an efficient approach to seismic retrofitting of structures based on the concept of reducing the seismic forces by lengthening the structural fundamental vibration period. However, superstructures may collide with each other under seismic excitation as ...
Story-added type apartments have recently been introduced as an option to resolve the housing supply shortage in areas that are undergoing rapid industrialization and urbanization. However, infrastructure of old apartment buildings (>20 years old) makes it difficult introduce convenient facilities recent technologies such those involving Internet Things augmented realities. Applying existing...
One of the most successful means of protecting structures against severe seismic events is base isolation. However, optimal design of base isolation systems depends on the magnitude of the design level earthquake that is considered. The features of an isolation system designed for an El Centro-type earthquake typically will not be optimal for a Northridge-type earthquake and vice versa. To be e...
The Bolu viaduct is a 2.3 km long seismically isolated structure whose construction was nearly complete when it was struck by the 1999 Duzce earthquake in Turkey. It suffered complete failure of the seismic isolation system and narrowly avoided total collapse due to excessive superstructure movement. This paper presents an evaluation of the design of the viaducts seismic isolation system and a...
In order to improve the effect of isolation structure, the principles and behaviours of the base-isolation system are studied, and the types and characteristics of the base-isolation are also discussed. Compared to the traditional aseismatic structures, the base isolation structures decrease the seismic response obviously: the total structural aseismatic value decreases to 1/4-1/32 and the seis...
A new seismic isolation system, TAMA Seismic Attenuation System (TAMA-SAS), was installed to TAMA300 in order to improve the sensitivity at low frequencies. Inertial damping is one of the hierarchical control systems of the TAMA-SAS which are employed to give full play to its ability. We have established two servo loops to control the Inverted Pendulum (IP) which composes the SAS. One is the se...
seismic retrofit strategies have been developed in the past few decades following the introduction of new seismic provisions and the availability of advanced materials and methods. it can be observed that new approaches to deal with more lateral forces are more innovative and more energy absorbent. in line with this, there is a growing trend toward the use of steel shear walls as a system with ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید