We summarize the formalism of collimator wakefields and their effect on beams that are near the center of the collimator gap, and apply the formalism to the TESLA, NLC, and CLIC collimation systems. Collimator Wakefield Calculations for ILC-TRC Report
UNLABELLED In SPECT using high-energy photon-emitting isotopes, such as (131)I, parallel-hole collimators with thick septa are required to limit septal penetration, at the cost of sensitivity and resolution. This study investigated a parallel-hole collimator with cone-shaped holes, which was designed to limit collimator penetration while preserving resolution and sensitivity. The objective was ...
The precision alignment of high-performance, wide-field optical systems is generally a difficult and often laborious process. We report a new merit function regression method that has the potential to bring to such an optical alignment process higher efficiency and accuracy than the conventional sensitivity table method. The technique uses actively damped least square algorithm to minimize the ...
Due to the collimator aperture, spatial resolution of SPECT data varies with source-to-detector distance. Since the radius of detector rotation is bigger when scanning larger patients, spatial resolution is degraded in these cases. Emitted gamma rays travel not only along the central axis of the collimator hole but also off-axis due to the collimator aperture. However, an off-axis ray at one an...
Practical quantitative measurement of graticule misalignment relative to collimator axis of rotation
We design a practical procedure for measuring translational and rotational misalignment of graticule with collimator axis of rotation and collimator jaws, respectively. The procedure's quantitative results are accurate to less than 0.2 mm (at isocenter) and do not assume alignment of radiation focal spot with collimator axis of rotation. When provided with these quantitative results, the manufa...
A specially designed high resolution converging collimator having a focal length of 50 cm has been evaluated for cone beam single photon emission computed tomography (SPECT). The focal region was investigated by imaging a point source placed at the expected focal point and along the central ray of the collimator in front of and behind the focal point. Technetium-99m point source sensitivities m...
A long bore fan beam collimator for imaging the head was designed and constructed for a SPECT system with a rotating scintillation camera. In order to avoid the patient's shoulder during rotation of the camera with a thick camera housing, the long bore design is necessary to allow the collimator to get close to the patient's head for improved spatial resolution. Operating at the minimum radius ...
in this thesis, structural, electronical, and optical properties of inverse pervskite(ca3pbo) in cubic phase have been investigated.the calculation have been done based on density functional theory and according to generalized gradiant approximate (gga) as correlating potential. in order to calculate the configurations, implementing in the wien2k code have been used from 2013 version. first of ...
UNLABELLED This study was performed to investigate the usefulness of a general-purpose medium-energy (ME) collimator for the accurate localization of the sentinel lymph node (SLN) in breast cancer patients. METHODS We compared phantom images and lymphoscintigraphy images obtained under different conditions for a patient with breast cancer. Comparisons were performed between 2 cameras, between...