نتایج جستجو برای: enhanced dynamic wedge

تعداد نتایج: 749734  

Journal: :Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology 2013
Anna Kowalik Marcin Litoborski

BACKGROUND The aim of the modern radiotherapy is to get a homogenous dose distribution in PTV, which is obtained by using for example physical or dynamic wedges. The using of a physical wedge has provided such isodose distributions but their use resulted in detrimental dosimetric consequences, for example beam hardening effects and practical consequences of filter handling or possible misalignm...

Azin Shamsi Jafar Fatahiasl Mohammad Ali Behrooz Mohammad Javad Tahmasebi Birgani Neda Abdalvand Reza Maskny Shole Arvandi

Introduction: Wedge filters are commonly used in radiation oncology for eliminating hot spots and creating a uniform dose distribution in optimizing isodose curves in the target volume for clinical aspects. These are some limited standard physical wedges (15°, 30°, 45°, 60°), or creating an arbitrary wedge angle, like motorized wedge or dynamic wedge, ... The new formulation is...

2012
Shuo Ma

[1] Dynamic pore pressure changes in the overriding wedge above a shallow-dipping plate interface significantly affect the rupture dynamics of shallow subduction zone earthquakes and their tsunamigenesis. For a wedge on the verge of Coulomb failure everywhere including the basal fault, the dynamic pore pressure increase due to up-dip rupture propagation leads to widespread yielding within the w...

2006
Ivan A. Brezovich Richard A. Popple Jun Duan

A method is proposed for generating dynamic wedges spanning the entire field width, defined as the collimator opening in the wedged direction, without changes to existing hardware. The technique approximates the fluence pattern of a dynamic wedge by sequentially closing the leaves of a 120-leaf multileaf collimator (MLC). Closure times for the individual leaves were derived by extending the seg...

2018
Zhenia Gopalakrishnan Raghuram K. Nair P. Raghukumar B. Sarin

The aim of this study is to compare the physical wedge (PW) with enhanced dynamic wedge (EDW) to determine the difference in the dose distribution affecting the treated breast and the contralateral breast, lungs, heart, esophagus, spine, and surrounding skin in the radiotherapy of breast cancer. Computed tomography (CT) data sets of 30 breast cancer patients were selected from the database for ...

2006
Paola Caprile Carlos Daniel Venencia Pelayo Besa

We used the two available calculation algorithms of the Varian Eclipse 7.3 three-dimensional (3D) treatment planning system (TPS), the anisotropic analytic algorithm (AAA) and pencil-beam convolution (PBC), to compare measured and calculated two-dimensional enhanced dynamic wedge (2D EDW) dose distributions, plus implementation of the dynamic wedge into the TPS. Measurements were carried out fo...

Journal: :iranian journal of radiation research 0
m. hajizadeh saffar medical physics department, mashhad university of medical sciences, mashhad, iran m.r. ghavamnasiri h. gholamhosseinian

background: in radiotherapy, wedge filters are used for optimizing the tumor dose distribution in patients. the attenuation in beam intensity due to the presence of wedge filter is compensated by means of a wedge factor measured at the central axis of the beam. the field size, depth and ssd dependence of wedge factor have been assessed for 9mv radiations of neptun pc linear accelerator. materia...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید