نتایج جستجو برای: anthropomorphic head phantom

تعداد نتایج: 185703  

2012
Ming X. Jia Xu Zhang Na Li Cheng B. Han

The purpose of this study was to investigate the impact of different CBCT imaging monitor units (MUs), reconstruction slice thicknesses, and planning CT slice thicknesses on the positioning accuracy of a megavoltage cone-beam computed tomography (MV-CBCT) system in image-guided radiation therapy (IGRT) in head-and-neck patients. The MV-CBCT system was a Siemens MVision, a commercial system inte...

Journal: :Journal of magnetic resonance imaging : JMRI 2011
Nolan E Swailes Matthew Ethan MacDonald Richard Frayne

PURPOSE To develop an anthropomorphic phantom to simulate heart, lung, and blood motion. Magnetic resonance imaging (MRI) is sensitive to image distortion and artifacts caused by motion. Imaging phantoms are used to test new sequences, but generally, these phantoms lack physiological motion. For the validation of new MR-based endovascular interventional and other techniques, we developed a dyna...

Journal: :Medical physics 2016
D Branco P Taylor S Frank H Li X Zhang H Mehrens M Guindani D Followill

PURPOSE To design a Head and Neck (H&N) anthropomorphic QA phantom that the Imaging and Radiation Oncology Core Houston (IROC-H) can use to verify the quality of intensity modulated proton therapy (IMPT) H&N treatments for institutions participating in NCI clinical trials. METHODS The phantom was created to serve as a remote auditing tool for IROC-H to evaluate an institution's IMPT planning ...

Journal: :Journal of physics 2022

Abstract In the clinic, routine quality assurance tests ensure proper functioning of each individual aspect a radiation therapy treatment delivery. However, these may not guarantee an accurate this work, we present design and application head phantom (using 3D printing technology) developed for end-to-end stereotactic brain metastases, coupled with inserts ion chamber, film gel dosimeters. The ...

2014
Khalid Iqbal Kent A Gifford Geoffrey Ibbott Ryan L Grant Saeed Ahmad Buzdar

This work presents a comparison of an anthropomorphic PRESAGE® dosimeter and radiochromic film measurements with a commercial treatment planning system to determine the feasibility of PRESAGE® for 3D dosimetry in breast IMRT. An anthropomorphic PRESAGE® phantom was created in the shape of a breast phantom. A five-field IMRT plan was generated with a commercially available treatment planning sys...

Mohamad Yousefi Sooteh Nader Riahi Alam Sadegh Shurche

Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...

Journal: :Medical physics 2011
Ann-Katherine Carton Predrag Bakic Christer Ullberg Helen Derand Andrew D A Maidment

PURPOSE Develop a technique to fabricate a 3D anthropomorphic breast phantom with known ground truth for image quality assessment of 2D and 3D breast x-ray imaging systems. METHODS The phantom design is based on an existing computer model that can generate breast voxel phantoms of varying composition, size, and shape. The physical phantom is produced in two steps. First, the portion of the vo...

2012
Claudia C. Brunner Raymond J. Acciavatti Predrag R. Bakic Andrew D. A. Maidment Mark B. Williams Richard Kaczmarek Kish Chakrabarti

We investigated the appropriateness of four different mammography phantoms for image quality evaluation in Digital Breast Tomosynthesis (DBT). We tested the CIRS BR3D phantom, the ACR Prototype FFDM Accreditation Phantom, the Penn anthropomorphic breast phantom and the Quart mam/digi EPQC phantom. This work discusses the advantages and shortcomings of each phantom and concludes that none of the...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید