نتایج جستجو برای: air kerma strength

تعداد نتایج: 408460  

Journal: :JACC. Cardiovascular interventions 2013
Sanjit S Jolly John Cairns Kari Niemela Philippe Gabriel Steg Madhu K Natarajan Asim N Cheema Sunil V Rao Warren J Cantor Vladimír Džavík Andrzej Budaj Tej Sheth Vicent Valentin Anthony Fung Petr Widimsky Emile Ferrari Peggy Gao Barbara Jedrzejowski Shamir R Mehta

OBJECTIVES The authors sought to compare the radiation dose between radial and femoral access. BACKGROUND Small trials have shown an increase in the radiation dose with radial compared with femoral access, but many were performed during the operators' learning curve of radial access. METHODS Patients were randomized to radial or femoral access, as a part of the RIVAL (RadIal Vs. femorAL) tr...

2016
Liyun Chang Sheng-Yow Ho Tsair-Fwu Lee Hueisch-Jy Ding Pang-Yu Chen

A comprehensive review for the in-air calibration of an Ir-192 high-dose-rate brachytherapy source in terms of air kerma strength (AKS) and reference air kerma rate (RAKR) using the Farmer chamber was conducted. The reviewed calibration methods include the National Physical Laboratory (NPL) calibration standard in the UK, the 7-distance technique with the standard calibration of the National In...

2009
Mario Ciocca Guido Pedroli Roberto Orecchia Andrea Guido Federica Cattani Raffaella Cambria Umberto Veronesi

The aim of this study was to perform a detailed analysis of the air kerma values around a Liac mobile linear accelerator working in a conventional operating room (OR) for IORT. The Liac delivers electron beams at 4, 6, 8 and 10 MeV. A radiation survey to determine photon leakage and scatter consisted of air kerma measurements on a spherical surface of 1.5 m radius, centered on the titanium exit...

2008
Tania A. C. Furquim Ricardo A. Terini Silvio B. Herdade

Mammography, using X-rays, is routinely utilized for screening of patients for prevention of breast cancer. Nevertheless, there is a small but significant risk of radiation induced carcinogenenesis associated with radiation exposure of the breast, being glandular tissue the most sensitive one among the tissues composing breast. Risk estimation in mammography may be determined by the mean absorb...

Journal: :Journal of vascular and interventional radiology : JVIR 2012
Donald L Miller Stephen Balter Robert G Dixon Boris Nikolic Gabriel Bartal John F Cardella Lawrence T Dauer Michael S Stecker

ACR American College of Radiology, CRCPD Conference of Radiation Control Program Directors, FDA Food and Drug Administration, ICRU International Commission on Radiation Units and Measurements, IEC International Electrotechnical Commission, IRP interventional reference point, Ka,r total air kerma at the interventional reference point, NCRP National Council on Radiation Protection and Measurement...

2014
Sudhir Kumar D. Datta S. D. Sharma G. Chourasiya D. A. R. Babu D. N. Sharma

Verification of the strength of high dose rate (HDR) (192)Ir brachytherapy sources on receipt from the vendor is an important component of institutional quality assurance program. Either reference air-kerma rate (RAKR) or air-kerma strength (AKS) is the recommended quantity to specify the strength of gamma-emitting brachytherapy sources. The use of Farmer-type cylindrical ionization chamber of ...

Journal: :Journal of Research of the National Institute of Standards and Technology 2003

2007
R. H. Menk

A dosimetric procedure to assure the traceability to the air-kerma standard of the measurements performed in synchrotron radiation beams, was implemented at the “Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti” of ENEA (INMRI-ENEA). To this purpose, absolute air-kerma measurements by the ENEA standard free-air chamber for low energy x-rays have been performed at the SYRMEP (SYnchro...

2001
Charles S. Mayo Kenneth Ulin

A method is presented for checking the treatment time calculation for high dose rate (HDR) vaginal cylinder treatments. The method represents an independent check of the HDR planning system and can take into account nonuniform isodose line coverage around the cylinder. Only the air kerma strength of the source and information that is available from the written directive are required. The maximu...

2003
D. T. Burns M. O’Brien P. Lamperti M. Boutillon

The air-kerma standards used for the measurement of medium-energy x rays were compared at the National Institute of Standards and Technology (NIST) and at the Bureau International des Poids et Mesures (BIPM). The comparison involved a series of measurements at the BIPM and the NIST using the air-kerma standards and two NIST reference-class transfer ionization standards. Reference beam qualities...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید