نتایج جستجو برای: ultrasonic pachymetry

تعداد نتایج: 29317  

Journal: :بینا 0
حمید نوروزی h norouzi تهران- خیابان شهید مدنی- بیمارستان امام حسین (ع) ژاله رجوی j rajavi تهران- خیابان شهید مدنی- بیمارستان امام حسین (ع) محمدعلی اخوت پور ma okhovatpour تهران- خیابان شهید مدنی- بیمارستان امام حسین (ع)

purpose: to evaluate corneal thickness changes after soft contact lens (scl) removal in lasik candidates. methods: fifty lasik candidates (100 eyes) with history of daily wear scl for at least 6 months were enrolled in this descriptive study. central corneal thickness was measured by ultrasonic pachymetry immediately after lens removal and then repeated daily at the same time, until the thickne...

Journal: :Bulletin de la Societe belge d'ophtalmologie 2001
G Sallet

In 100 eyes of 50 patients central corneal thickness was measured comparing optical to ultrasound pachymetry. With optical pachymetry the values were 1 to 40 micrometer (microns) lower in 64 eyes compared to ultrasound pachymetry. With ultrasound pachymetry the values were 1 to 18 microns lower in 26 eyes compared to optical pachymetry. In 10 cases no difference in pachymetry readings was seen ...

Journal: : 2021

Objective: To investigate corneal structural in patients with Familial Mediterranean Fever (FMF). Methods: This case-control study included 64 FMF and, 49 age and gender similar healthy subjects without any eye disease. Endothelial cell density (ECD), the coefficient of variation size (CV) percentage hexagonality were measured by non-contact specular microscopy, central thickness (CCT) was ultr...

Journal: :The British journal of ophthalmology 2001
A C Ventura M Böhnke D S Mojon

BACKGROUND/AIMS Recent studies have revealed patients with ocular hypertension to have thicker than normal central corneas and those with normal tension glaucoma to have thinner than normal ones, as determined by ultrasonic pachymetry. Since corneal thickness measurements and applanation tonometric estimates of intraocular pressure (IOP) correlate positively, monitoring of the former parameter ...

Journal: :Brazilian journal of medical and biological research = Revista brasileira de pesquisas medicas e biologicas 2006
G C Almeida S J Faria e Souza

Our objective was to study the effect of dorzolamide on corneal hydration in an 18-week controlled experiment using ultrasonic pachymetry. Twenty-eight male rabbits were divided randomly into four groups. The 7 rabbits in each group received eye drops containing either 2% (w/v) dorzolamide or placebo in their right eye, or in their left eye. The 2% dorzolamide rabbits were treated every 8 h. Fe...

2014
Nader Nassiri Kourosh Sheibani Sare Safi Saman Nassiri Alireza Ziaee Farnaz Haji Shiva Mehravaran Nariman Nassiri

PURPOSE To determine inter-device agreement for central corneal thickness (CCT) measurement among ultrasound pachymetry, rotating Scheimpflug imaging (Pentacam, Oculus, Wetzlar, Germany), and scanning slit corneal topography (Orbscan II, Bausch & Lomb, Rochester, NY, USA) in highly myopic eyes before and after photorefractive keratectomy (PRK). METHODS This prospective comparative study inclu...

2012
Jin Pyo Hong Sang Min Nam Tae-Im Kim Kyoung Yul Seo Sang Yeop Lee Alessandro Meduri Eung Kweon Kim

PURPOSE To evaluate reliability of Fourier-domain optical coherence tomography (OCT) (RTVue), time-domain OCT (Visante), and slit-lamp adapted ultrasonic pachymetry (SL-US) in the measurement of central corneal thickness (CCT). MATERIALS AND METHODS Thirty healthy volunteers visited our clinic 3 times and fifty eyes were measured by one physician. RTVue and Visante were randomly performed, an...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید