Polynuclear aromatic hydrocarbons (PAHs) from sequestered MV Selendang Ayu oil were biologically available in 2008, 3.6 y after it was spilled along Unalaska Island, Alaska. Thermodynamically driven weathering was the most probable mechanism of organism exposure to PAHs. Alkane and PAH composition in oil changed over time as smaller constituents were preferentially lost, indicative of weatherin...
Passive samplers have been shown to be an inexpensive alternative to direct sampling. Diffusion denuders have been developed to measure the concentration of species such as ammonia (NH3), which is in equilibrium with particulate ammonium nitrate. Conventional denuder sampling has required active sampling that inherently requires air pumps and, therefore, electrical power. To estimate emissions ...
Pollution from highway stormwater runoff has been an increasing area of concern. Many structural Best Management Practices (BMPs) have been implemented for stormwater treatment and management. One challenge for these BMPs is to sample stormwater and monitor BMP performance. The main objective of this study was to evaluate the feasibility of using polyurethane foam (PUF) passive samplers (PSs) f...
Volatile losses were measured from polydimethylsiloxane (PDMS) passive samplers during determination of contaminant porewater concentrations in sediments. Volatile losses could occur between the time of retrieval and processing of the passive sampler or in intertidal environments where the passive sampler could potentially be exposed above the water surface at low tide. A model was developed to...
Active-sampling approaches are commonly used for personal monitoring, but are limited by energy usage and data that may not represent an individual's exposure or bioavailable concentrations. Current passive techniques often involve extensive preparation, or are developed for only a small number of targeted compounds. In this work, we present a novel application for measuring bioavailable exposu...
Two modified passive samplers were evaluated at multiple field locations. The sampling rate (SR) of the modified polyurethane foam (PUF)-disk passive sampler for total gaseous mercury (TGM) using gold-coated quartz fiber filters (GcQFF) and gaseous oxidized mercury (GOM) using ion-exchange membranes (IEM) were 6.4 ± 1.4 and 15.3 ± 0.3 m(3) day(-1), respectively. The relative percent difference ...
Robust low-cost sampler systems allowing for monitoring of air pollutants important for air quality resulting from forest fires and urban/agricultural activities in remote locations were tested and developed. The main emphasis was placed on passive samplers for ozone and nitrogenous pollutants (nitrogen oxides, ammonia and nitric acid vapor). In addition, a system for evaluation of total inputs...
Little is known of the distribution of persistent organic pollutants (POPs) in the deep ocean. Polyethylene passive samplers were used to detect the vertical distribution of truly dissolved POPs at two sites in the Atlantic Ocean. Samplers were deployed at five depths covering 26-2535 m in the northern Atlantic and Tropical Atlantic, in approximately one year deployments. Samplers of different ...