نتایج جستجو برای: ebt3

تعداد نتایج: 189  

2017
A. Lagzda R. M. Jones D. Angal-Kalinin J. Jones A. Aitkenhead K. Kirkby R. McKay M. van Herk S. Zeeshan

We investigated the effects of heterogeneous regions on dose deposition of very high-energy electrons (VHEE) using both Geant4 simulations and experiments performed at the CALIFES facility at CERN. Small air and acetal plastic (bone equivalent) cavities were embedded in a water phantom and irradiated with a 197 MeV electron beam. Experimentally determined transverse dose profiles were acquired ...

2016
James L. Gräfe Jennifer Owen J. Eduardo Villarreal‐Barajas Rao F.H. Khan

A new megavoltage (MV) energy was recently introduced on Varian TrueBeam linear accelerators for imaging applications. This work describes the experimental characterization of a 2.5 MV inline portal imaging beam for commissioning, routine clinical use, and quality assurance purposes. The beam quality of the 2.5 MV beam was determined by measuring a percent depth dose, PDD, in water phantom for ...

Journal: :Precision radiation oncology 2023

A newly developed GafchromicTM EBT4 film model was released recently. According to the vendor-stated specifications, this new maintains major features of its more recent predecessor, EBT3, but has a great improvement in signal-to-noise ratio (SNR). The purpose study fully characterize by testing dose response dependence on beam energy using clinical photon and electron beams validating SNR. In ...

2015
Pietro Mancosu Pierina Navarria Giacomo Reggiori Luca Cozzi Antonella Fogliata Anna Gaudino Francesca Lobefalo Lucia Paganini Valentina Palumbo Barbara Sarina Antonella Stravato Luca Castagna Stefano Tomatis Marta Scorsetti

BACKGROUND Total marrow (lymph-nodes) irradiation (TMI-TMLI) by volumetric modulated arc therapy (VMAT) was shown to be feasible by dosimetric feasibility studies. It was demonstrated that several partially overlapping arcs with different isocenters are required to achieve the desired coverage of the hematopoietic or lymphoid tissues targets and to spare the neighbouring healthy tissues. The ef...

2015
Yoshinobu Shimohigashi Fujio Araki Masato Maruyama Yuji Nakaguchi Satoshi Kuwahara Nozomu Nagasue Yudai Kai

The purpose of this study was to evaluate a single-scan protocol using Gafchromic EBT3 film (EBT3) by comparing it with the commonly used 24-hr measurement protocol for radiochromic film dosimetry. Radiochromic film is generally scanned 24 hr after film exposure (24-hr protocol). The single-scan protocol enables measurement results within a short time using only the verification film, one calib...

2013
Guerda Massillon-JL Sou-Tung Chiu-Tsao Ivan Domingo-Muñoz Maria F. Chan

Purpose: To study and compare the dose response curves of the new GafChromic EBT3 film for megavoltage and kilovoltage x-ray beams, with different spatial resolutions. Methods: EBT3 films (lot#A101711-02) were exposed to each x-ray beam (6 MV, 15 MV, and 50 kV) at 7 dose values (50 3200 cGy). Each film piece was scanned three consecutive times in the center of Epson 10000XL flatbed scanner in 4...

2016
Ning Wen Siming Lu Jinkoo Kim Yujiao Qin Yimei Huang Bo Zhao Chang Liu Indrin J Chetty

PURPOSE The purpose of this study is to evaluate the dosimetric uncertainty associated with Gafchromic™ (EBT3) films and establish a practical and efficient film dosimetry protocol for Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiotherapy (SBRT). METHOD AND MATERIALS EBT3 films were irradiated at each of seven different dose levels between 1 and 15 Gy with open fields and standar...

2015
Toshizo Katsuda Rumi Gotanda Tatsuhiro Gotanda Takuya Akagawa Nobuyoshi Tanki Tadao Kuwano Kouichi Yabunaka

Gafchromic films are used for X-ray dose measurements during diagnostic examinations and have begun to be used for three-dimensional X-ray dose measurements using the high-resolution characteristics of Gafchromic films for computed tomography. However, the problem of unevenness in Gafchromic film active layers needs to be resolved. Double exposures using X-rays are performed during therapeutic ...

Journal: :Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics 2013
J Sorriaux A Kacperek S Rossomme J A Lee D Bertrand S Vynckier E Sterpin

PURPOSE To evaluate the uncertainties and characteristics of radiochromic film-based dosimetry system using the EBT3 model Gafchromic(®) film in therapy photon, electron and proton beams. MATERIAL AND METHODS EBT3 films were read using an EPSON Expression 10000XL/PRO scanner. They were irradiated in five beams, an Elekta SL25 6 MV and 18 MV photon beam, an IBA 100 MeV 5 × 5 cm(2) proton beam ...

2017
Yinghui Li Lixin Chen Jinhan Zhu Xiaowei Liu

PURPOSE The aim of this study was to combine a set of methods for use of radiochromic film dosimetry, including calibration, correction for lateral effects and a proposed triple-channel analysis. These methods can be applied to GAFCHROMIC EBT3 film dosimetry for radiation field analysis and verification of IMRT plans. METHODS A single-film exposure was used to achieve dose calibration, and th...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید