نتایج جستجو برای: beamnrc simulation

تعداد نتایج: 559052  

Mahmood Allahverdi, Micaeil Mollazadeh Mohammadreza Ay Nader Riahi Alam Tayyeb Allahverdi Pourfallah,

Introduction: GafChromic EBT films are one of the self-developing and modern films commercially available for dosimetric verification of treatment planning systems (TPSs). Their high spatial resolution, low energy dependence and near-tissue equivalence make them suitable for verification of dose distributions in radiation therapy. This study was designed to evaluate the dosimetric parameters of...

Journal: :Open Journal of Radiology 2022

Context: Medical imaging has a wide range of applications in today’s society. Basic projectional radiography, CT scans, mammograms and other advanced technologies all use x-rays to create large number examinations every day across the world. The most essential component such medical equipment is x-ray tube, which creates produces x-rays. Objective: We describe investigate an abstract model-geom...

Introdution: The aim of this study was to evaluate and benchmark EGSnrc code in the simulation of 18 MV photon beam produced by Siemens Oncor® linear accelerator. Methods: This study was conducted in a comparative and simulation based on experience method. The Beamnrc code was used to model the accelerator head and generate phase space files. The phase space files were obtained with the fo...

Gh. Geraily, Gh.R. Fallah Mohammadi1, N. Riyahi Alam, R. Paydar,

Background:  This study presents patient specific and organ dose estimation in computed tomography (CT) imaging of thorax directly from patient CT image using Monte Carlo simulation.  Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. Materials and Methods: EGSnrc /BEAMnr...

2012
Hamed Babapour Tayyeb Allahverdi Pourfallah Ali Shabestani Monfared Ali-Reza Shirazi

Introduction Superficial X-ray therapy is one of the most important treatment methods in radiotherapy especially in the treatment of superficial skin lesions (Up to 300 kVp). Quality of the X-ray beam that can be expressed by Half-Value Layer (HVL), are important indices for this type of treatment effective energy of photon and Homogeneity Coefficient (HC). Materials and Methods The HC of the s...

2012
Tayeb Allahverdi Pourfallah Mahmoud Allahverdi Mohammad Hasan Zahmatkesh

Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...

Journal: :iranian journal of medical physics 0
ali shabestani monfared biochemistry and biophysics department, babol university of medical sciences, shahid rajaee oncology hospital, babolsar, iran

introduction superficial x-ray therapy is one of the most important treatment methods in radiotherapy especially in the treatment of superficial skin lesions (up to 300 kvp). quality of the x-ray beam that can be expressed by half-value layer (hvl), are important indices for this type of treatment effective energy of photon and homogeneity coefficient (hc). materials and methods the hc of the s...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه صنعت آب و برق (شهید عباسپور) - دانشکده مهندسی برق و کامپیوتر 1392

abstract according to increase in electricity consumption in one hand and power systemsreliability importance in another , fault location detection techniqueshave beenrecentlytaken to consideration. an algorithm based on collected data from both transmission line endsproposed in this thesis. in order to reducecapacitance effects of transmission line, distributed parametersof transmission line...

2013
W. Laub

Purpose Monte Carlo (MC) models of radiotherapy beams can be used as a comparison benchmark for other dose calculation methods. In any such comparison process, the degree to which an identified deviation represents an actual error will depend upon the accuracy of the benchmark. As part of an ongoing dosimetric study, we have sought to model the standard Varian Clinac 6MV beam as accurately as p...

Abolfzal Nickfarjam Daniel Markel, Mahdieh Afkhami Ardakani Milad Najafzadeh, Mohammad Haghparast Mojtaba Hoseini-Ghahfarokhi,

Introduction: The aim of this study was to investigate the initial electron beam parameters for Monte Carlo model of 6MV photon beam produced by Siemens Oncor® linear accelerator.   Materials and Methods: In this study, the EGSnrc Monte Carlo user codes BEAMnrc and DOSXYZnrc were used. The beamnrc code were used for modelling of a 6 MV photon beam produced by...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید