نتایج جستجو برای: artisan iol

تعداد نتایج: 2687  

Journal: :Ophthalmology 2003
Ruchi Saxena Monika Landesz Bastiaantje Noordzij Gregorius P M Luyten

PURPOSE We report the postoperative results of the Artisan Hyperopia phakic intraocular lens (IOL; model 203W; Ophtec, Groningen, The Netherlands). DESIGN Prospective, nonrandomized trial. PARTICIPANTS Twenty-six eyes of 13 self-selected patients with refractive error ranging from +3.00 to +11.00 diopters (D). INTERVENTION Patients with hypermetropia were implanted with the Artisan Hypero...

Journal: :Acta ophthalmologica Scandinavica 2006
Paul Dighiero Sébastien Guigou Martial Mercie Benoit Briat Pierre Ellies Jean-Jacques Gicquel

PURPOSE To present a new surgical technique combining penetrating keratoplasty and open-sky posterior iris fixation of the Artisan iris-claw intraocular lens (IOL) for treatment of pseudophakic bullous keratopathy in a case series of five patients. METHODS A graft diameter of 8.25 mm was chosen. The formerly implanted angle-supported IOL was removed. The IOL was enclosed, entrapping a fractio...

Journal: :journal of current ophthalmology 0
حسن هاشمی hassan hashemi منصور طاهرزاده mansour taherzadeh مهدی خبازخوب mehdi khabazkhoob

purpose : to determine and evaluate the visual acuity (va) and refracion of correcting compound severe myopic astigmatism with the artisan toric intraocular lenses (iols) methods : in this noncontrolled clinical trial, 15 patients with severe astigmatism and at least 2.0 diopters (d) of astigmatism were enrolled. all patients met the inclusion criteria. artisan toric iol implantation was recomm...

Journal: :Journal of cataract and refractive surgery 2008
Thomas Kohnen Magda Cichocki Michael J Koss

PURPOSE To evaluate the postoperative intraocular positional stability of 1 rigid poly(methyl methacrylate) (PMMA) phakic intraocular lens (pIOL) model and 2 foldable polysilicone-PMMA iris-fixated pIOL models. SETTING Department of Ophthalmology, Johann Wolfgang Goethe-University Frankfurt am Main, Germany. METHODS One of 3 iris-fixated pIOL models (Artisan, Artiflex I, and Artiflex II, Op...

2013
Joo Youn Shin Jae Bum Lee Kyoung Yul Seo Eung Kweon Kim Tae-im Kim

PURPOSE To compare preoperative and postoperative ocular biometry in patients with iris-fixated phakic intraocular lens (pIOLs): Artisan and Artiflex. MATERIALS AND METHODS This study included 40 eyes with Artisan and 36 eyes with Artiflex pIOL implants. Anterior chamber depth (ACD) and axial length (AL) were measured by applanation ultrasonography (A-scan) and partial coherence interferometr...

Journal: :Journal of cataract and refractive surgery 2008
Nayyirih G Tahzib Scott M MacRae Geunyoung Yoon Tos T J M Berendschot Fred A G J Eggink Fred Hendrikse Rudy M M A Nuijts

PURPOSE To evaluate higher-order aberrations (HOAs) after implantation of Artiflex phakic intraocular lenses (pIOLs). SETTING Department of Ophthalmology, Academic Hospital Maastricht, Maastricht, The Netherlands. METHODS This retrospective comparative case series comprised 27 eyes (14 patients) that had Artiflex pIOL implantation and 22 eyes (13 patients) that had Artisan pIOL implantation...

Journal: :Journal of refractive surgery 2001
E M Chipont P García-Hermosa J L Alió

PURPOSE To report a case of reversal of myopic anisometropic amblyopia with phakic intraocular lens implantation. METHODS A 6-year-old boy with anisometropic amblyopia with spherical equivalent refraction of right eye: -14.00 -3.00 x 100 degrees, left eye: -0.50 -3.25 x 90 degrees, was treated for 2 years with occlusion to the left eye, with poor results. Refractive surgery was planned becaus...

2016
Dan Cao Hongyang Zhang Cheng Yang Liang Zhang

BACKGROUND Postoperative optic opacification of hydrophilic acrylic intraocular lenses (IOLs) is an uncommon complication leading to IOL explantation. In the past decade, several studies reported that the granular deposits responsible for the opacification were probably calcium and phosphate salts; however, the exact mechanism causing calcification of IOLs is unknown. The aim of this study is t...

Journal: :Ophthalmology 2006
Marjolijn C Bartels Ruchi Saxena Thomas J T P van den Berg Gabriel van Rij Paul G H Mulder Gregorius P M Luyten

PURPOSE To evaluate postoperative astigmatism with regard to incision-induced astigmatism and deviation in axial alignment with the use of preoperative limbal marking with the Javal keratometer (Haag Streit, Bern, Switzerland) in eyes implanted with the Artisan toric phakic intraocular lens (IOL) (Ophtec, Groningen, The Netherlands). DESIGN Prospective nonrandomized trial. PARTICIPANTS Fift...

Journal: :Indian journal of ophthalmology 2006
Sirisha Senthil Kasu Prasad Reddy

PURPOSE To evaluate the efficacy, safety, predictability and stability of implanting a polymethylmethacrylate phakic intraocular lens (PIOL) in high myopia. MATERIALS AND METHODS A retrospective analysis of the data of patients who underwent Artisan phakic IOL implantation between 2002 and 2003 with a follow-up of at least 24 months. RESULTS An Artisan myopia lens was implanted in 60 eyes o...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید