نتایج جستجو برای: transmitted dosimetry
تعداد نتایج: 67391 فیلتر نتایج به سال:
The OSL dosimetry technique with teeth has been validated against the EPR dosimetry technique through a measurement comparison performed on the same teeth. The OSL reconstructed doses were found to be in agreement with corresponding EPR doses. Minimum measurable doses for the OSL technique were estimated to be in the range 0.9e1.5 Gy for measurements made within 24 h post-exposure if OSL signal...
Nuclear medicine clinical practices for neoplasic disease diagnose and treatment are based on the incorporation of α , β and γ radiotracers and radiopharmaceuticals, which might be associated with potential damage. Thus, being necessary accurate dosimetry strategies. In vivo absorbed dose appears as an ideal solution. However, its implementation in clinics does not attain enough reliability. In...
Review is made of dosimetric studies of current optical fibre technology in radiotherapy for therapeutic applications, focusing particularly on in vivo dosimetry for prostate radiotherapy. We present the various sensor designs along with the main advantages and disadvantages associated with this technology. Optical fibres are ideally placed for applications in radiotherapy dosimetry; due to the...
Dosimetry is the process of calculating the effective radioactive dose that is applied to tumors and organs respectively as a patient undergoes a peptide receptor radionuclide therapy. This work presents the novel application software ‘DoSE8’ that was developed from our group and that incorporates all necessary image processing steps (registration and segmentation) and data handling for (partly...
We have formulated a unified dosimetry index (UDI) that computes, for any given treatment plan, its deviations in terms of dose coverage, conformity, homogeneity, and dose gradient vis-à-vis an ideal plan (which we define as a dosimetry plan of perfect dose coverage, conformity, homogeneity, and step-wise fall-off to zero dose outside the planning target volume). In order to validate the UDI sc...
Various neutron detectors for spectrometry, environmental dosimetry and personal dosimetry have been developed by our group. For high energy neutron spectrometry, spallation detectors of C and Bi, large plastic and NE-213 scintillators, self TOF detector have been used for neutron production and shielding experiments at several high energy accelerator facilities, ISIS of Rutherford Appleton Lab...
PURPOSE We recently developed a novel, open-source in vivo dosimetry that uses the electronic portal imaging device to detect dose delivery discrepancies. We applied our method on patients with rectal cancer treated on a belly board device. METHODS In vivo dosimetry was performed on 10 patients with rectal cancer treated prone on the belly board with a 4-field box arrangement. Portal images w...
Online light dosimetry with real-time feedback was applied for temoporfin-mediated interstitial photodynamic therapy (PDT) of dog prostate. The aim was to investigate the performance of online dosimetry by studying the correlation between light dose plans and the tissue response, i.e., extent of induced tissue necrosis and damage to surrounding organs at risk. Light-dose planning software provi...
A methodology for the dosimetric verification of micro-multileaf collimator MMLC) based intensity modulated radiation therapy (IMRT) plans intended for stereotactic applications is described. The procedure is similar to that of conventional IMRT patient-specific quality assurance with some notable exceptions. Relative dosimetry measurements are performed with radiographic film, a commercial fil...
BACKGROUND The accurate results of the individual doses in personal dosimety which are reported by the service providers in personal dosimetry are very important. There are national / international criteria for acceptable dosimetry system performance. Objective : In this research, the sources of uncertainties are identified, measured and calculated in a personal dosimetry system by TLD. METHO...
نمودار تعداد نتایج جستجو در هر سال