Journal: :journal of biomedical physics and engineering 0
s r mahdavi k keshavarzi e davani

objectives: the aim of this study was to verify the treatment planning systems (tpss). the next aim was to validate imsure qa software for patient-specific qa in radiotherapy clinics.  material and methods: we used imsure qa software (standard imaging, v 3.5) for verification of 92 non-imrt plans (540 fields) in 10 radiotherapy clinics. to validate the imsure, dose measurement was performed in ...

Journal: :iranian journal of radiation research 0
k.n. esnaashari department of medical physics tehran university of medical sciences, tehran, iran m. allahverdi department of medical physics tehran university of medical sciences, tehran, iran h. gharaati department of medical physics tehran university of medical sciences, tehran, iran m. shahriari department of medical radiation, shahid beheshti university, tehran, iran

background: stereotactic radiosurgery is an important clinical tool for the treatment of small lesions in the brain, including benign conditions, malignant and localized metastatic tumors. a dosimetry study was performed for elekta ‘synergy s ’ as a dedicated stereotactic radiosurgery unit, capable of generating circular radiation fields with diameters of 1-5 cm at isocentre using the beam/egs4...

Journal: :iranian journal of radiation research 0
m. ismail department of physics, the islamia university of bahawalpur, bahawalpur, pakistan m. afzal department of physics, the islamia university of bahawalpur, bahawalpur, pakistan m. nadeem bahawalpur institute of nuclear medicine and oncology (bino), bahawalpur, pakistan a.m. rana department of physics, bahauddin zakariya university, multan, pakistan s. amjad department of physics, the islamia university of bahawalpur, bahawalpur, pakistan s.a. buzdar department of physics, the islamia university of bahawalpur, bahawalpur, pakistan

background: radiotherapy treatment planning requires different dosimetric quantities as input in order to calculate a desired dose distribution. this study has been focused to evaluate the depth dose characteristics of superficial x-rays being used for radiotherapy treatment. materials and methods: computerized 3-d water phantom of multi-data system was used. the measurements were made through ...

Journal: :iranian journal of medical physics 0
mahbobeh nazarnejad science and research branch, islamic azad university, tehran, iran

introduction dosimetric accuracy is a major issue in the quality assurance (qa) program for treatment planning systems (tps). an important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. in brachytherapy (bt) of gynecological (gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...

Journal: :iranian journal of cancer prevention 0
hamideh nazemi-gelyan dept. of medical physics, semnan university of medical sciences, semnan, iran hadi hasanzadeh dept. of medical physics, semnan university of medical sciences, semnan, iran yasha makhdumi reza radiotherapy oncology charity center, mashhad, iran sara abdollahi dept. of radiotherapy, iran university of medical sciences, tehran, iran fatemeh akbari reza radiotherapy oncology charity center, mashhad, iran fatemeh varshoee-tabrizi reza radiotherapy oncology charity center, mashhad, iran

background: radiotherapy plays an important role in the management of most malignant and many benign primary central nervous system (cns) tumors. radiotherapy affects both tumor cells and uninvolved normal cells; so, it is important to estimate absorbed dose to organs at risk in this kind of treatment. the aim of this study was to determine the absorbed dose to chiasma, lens, optic nerve, retin...

Journal: :Magnetic resonance in medicine 2010
Samuel Dambreville Arlene B Chapman Vicente E Torres Bernard F King Ashley K Wallin David H Frakes Ajit P Yoganathan Sameera R Wijayawardana Kirk Easley Kyongtae T Bae Marijn E Brummer

This study evaluates reliability of current technology for measurement of renal arterial blood flow by breath-held velocity-encoded MRI. Overall accuracy was determined by comparing MRI measurements with known flow in controlled-flow-loop phantom studies. Measurements using prospective and retrospective gating methods were compared in phantom studies with pulsatile flow, not revealing significa...

2016
Jennifer R McKinney Marshall S Sussman Rahim Moineddin Afsaneh Amirabadi Tammy Rayner Andrea S Doria

OBJECTIVES To evaluate the accuracy of magnetic resonance imaging measurements of cartilage tissue-mimicking phantoms and to determine a combination of magnetic resonance imaging parameters to optimize accuracy while minimizing scan time. METHOD Edge dimensions from 4 rectangular agar phantoms ranging from 10.5 to 14.5 mm in length and 1.25 to 5.5 mm in width were independently measured by tw...

Journal: :Physiological measurement 2016
Justin Wagenaar Andy Adler

Electrical impedance tomography (EIT) uses body surface electrical stimulation and measurements to create conductivity images; it shows promise as a non-invasive technology to monitor the distribution of lung ventilation. Most applications of EIT have placed electrodes in a 2D ring around the thorax, and thus produced 2D cross-sectional images. These images are unable to distinguish out-of-plan...

Journal: :International journal of radiation oncology, biology, physics 2011
ChinLoon Ong Wilko F A R Verbakel Johan P Cuijpers Ben J Slotman Suresh Senan

PURPOSE Volumetric modulated arc therapy (RapidArc; Varian Medical Systems, Palo Alto, CA) allows fast delivery of stereotactic radiotherapy for Stage I lung tumors. We investigated discrepancies between the calculated and delivered dose distributions, as well as the dosimetric impact of leaf interplay with breathing-induced tumor motion. METHODS AND MATERIALS In 20 consecutive patients with ...

Journal: :Radiology 2008
Andrew E Anderson Benjamin J Ellis Christopher L Peters Jeffrey A Weiss

PURPOSE To prospectively assess in a phantom the reconstruction errors and detection limits of cartilage thickness measurements obtained with multidetector computed tomographic (CT) arthrography, as a function of contrast agent concentration, scanning direction, spatial resolution, joint spacing, and tube current, with known measurements as the reference standard. MATERIALS AND METHODS A phan...