نتایج جستجو برای: collimator responses

تعداد نتایج: 400367  

Akram Abehesht Saeed Sarkar Seyed Hassan Firouzabadi

By identifying the effect of any parameter such as distance, attenuation and scattering on the Line Spread Function (LSF), one can compensate the quantitative and qualitative destructive effect of such parameters by deconvolution method. Using a 99mTC line source, this study was performed on a single head ADAC SPECT system operating in planar mode. Variation of FWTM and FWHM and LSFs as a...

Journal: :Journal of Physics: Conference Series 2019

Journal: :Journal of Instrumentation 2021

In this work the concept of a novel slow neutron collimator and way to operate it are presented. The idea is based on possibility decouple device field-of-view from its collimation power. A multi-channel geometry proposed consisting chess-board structure where highly neutron-absorbing channels alternated air channels. borated polymer was purposely developed produce attenuating components in for...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2005
Youngho Seo Kenneth H Wong Mingshan Sun Benjamin L Franc Randall A Hawkins Bruce H Hasegawa

UNLABELLED (111)In-Capromab pendetide imaging is indicated for postprostatectomy patients at risk for residual or recurrent disease. However, this study is complicated by relatively long times for tumor uptake and background washout that require imaging to be performed several days after radiopharmaceutical administration. In addition, (111)In-capromab pendetide demonstrates uptake in normal st...

Journal: :iranian journal of nuclear medicine 2011
faraz kalantari hossein rajabi mohsen saghari alireza emami ardekani

introduction: monte carlo (mc) is the most common method for simulating virtual spect projections. it is useful for optimizing procedures, evaluating correction algorithms and more recently image reconstruction as a forward projector in iterative algorithms; however, the main drawback of mc is its long run time. we introduced a model based method considering the effect of body attenuation and i...

Journal: :iranian journal of radiation research 0
m.t. bahreyni toossi department of medical physics, mashhad university of medical sciences, mashhad a.r. khoshbin khoshnazar

background: a set of hardware stereotactic radiosurgery is designed and constructed. the scope of this article is to describe how we have designed and developed stereotactic collimation assembly for a 9 mv neptun 10 pc linac. materials and methods: one collimator holder and six collimators were made, with their radiation field diameter between 12.5 mm to 25 mm at isocenter level. beam data, suc...

2017
Taro Murai Yukiko Hattori Chikao Sugie Hiromitsu Iwata Michio Iwabuchi Yuta Shibamoto

Multileaf collimator (MLC) technology has been newly introduced with the Cyberknife system. This study investigated the advantages of this system compared with the conventional circular collimator (CC) system. Dosimetric comparisons of MLC and CC plans were carried out. First, to investigate suitable target sizes for the MLC mode, MLC and CC plans were generated using computed tomography (CT) i...

2005
Marina Chukalina Sergey Zaitsev Dmitry Nikolaev Alexandre Simionovici Maxim Knyazev C. J. Vanegas

In this paper we compare confocal apparatus tomography and computer tomography for medical use. Two aspects are illustrated: the process of image visualization and the dose deposition. The latter aspect is a damage factor of the object under investigation; it is why the data collection time is evaluated. Two principal tomography schemes are described and the expressions connecting the collected...

Journal: :Physical Review Accelerators and Beams 2017

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید