INTRODUCTION In India, official and centralized personnel monitoring service using film badge was started in 1952 by Bhabha Atomic Research Centre, Bombay (1). With the indigenous development of a TLD badge system (2) based on CaSO4:Dy Teflon disc dosimeter (3) exhibiting evident superiorities over film badge, replacement of film based individual dosimeter by TLD was initiated in 1975. At prese...
This work investigated the suitability of passive dosimeters for reference dosimetry in small fields with acceptable accuracy. Absorbed dose to water rate was determined in nine small radiation fields with diameters between 4 and 35 mm in a Leksell Gamma Knife (LGK) and a modified linear accelerator (linac) for stereotactic radiosurgery treatments. Measurements were made using Gafchromic film (...
Achievement of Quality Control Parameters for NIS Personal Thermoluminescence Dosimeter (TLD) System
This work intend to identify and follow up quality control parameters to improve thermoluminescence dosemeter (TLD) system used for personal dosimetry in ionizing radiation metrology laboratory (IRML). Characterization of personal dosimetry system has presented in terms of the stability of reader calibration factors, linearity of response for Cs as reference radiation source, energy and angular...
The purpose of this study was to determine the dose to the contralateral breast during accelerated partial breast irradiation (APBI) and to compare it to external beam-published values. Thermoluminescent dosimeter (TLD) packets were used to measure the dose to the most medial aspect of the contralateral breast during APBI simulation, daily quality assurance (QA), and treatment. All patients in ...
The percentage depth dose in the build-up region and the surface dose for the 6-MV photon beam from a Varian Clinac 23EX medical linear accelerator was investigated for square field sizes of 5 × 5, 10 × 10, 15 × 15 and 20 × 20 cm(2)using the EGS4nrc Monte Carlo (MC) simulation package. The depth dose was found to change rapidly in the build-up region, and the percentage surface dose increased p...
Gamma index pass rates were evaluated for an anthropomorphic phantom using both 2D and 3D calculations. The phantom was irradiated with the traditional dosimetry insert loaded with radiochromic film and TLD, and then with a 3D dosimetry insert. A comparison with the calculated dose distribution showed that both the PRESAGE® dosimeter and the film and TLD system agreed with the plan to within 5%...
The response of the passive photodosimeter with halide film characterized by a high optical density of about 0.550 ± 0.007 was analysed on dose ranges, taking into consideration the filters of the dosimetric badge, and finally compared with the thermoluminescent dosimeter (TLD). In this respect the dosimeters were exposed to a Cs 137 calibration radioactive source at different points within (0....