نتایج جستجو برای: tibia plateau fracture

تعداد نتایج: 131167  

2004
Dong-Gyu Ahn Jun-Young Lee Dong-Yol Yang

This paper describes orthopedic surgical planning based on the integration of RE and RP. Using symmetrical characteristics of the human body, CAD data of the original bone without damages for the injured extent are generated from a mirror transformation of undamaged bone data for the uninjured extent. The physical model before the injury is manufactured from RP apparatus. Surgical planning, suc...

Journal: :journal of research in medical sciences 0
mohammad hadi nouraei alireza hosseini general physician, department of orthopedic surgery, medical school,isfahan university of medical sciences, isfahan, iran. abolghasem zarezadeh mohammad zahiri

background: floating knee, referred to as ipsilateral fractures of the femur and tibia, is usually associated with several complications and mortality. this study was designed to present our experience with treatment of this injury throughout; age, sex, mechanism of injury, associated injuries, method and results of treatment, and complications of floating knee are discussed. materials and meth...

Journal: :Revista brasileira de ortopedia 2010
Glauco Pauka Mello Helio Ayabe Sonehara Mario Armani Neto

This is a case report on a giant cell tumor of the juxta-articular proximal tibia with a pathological fracture. A female patient presented pain and increased local volume after falling from her own height. She underwent clinical examination, radiographic examination and puncture biopsy. A diagnosis of giant cell tumor was made. The patient was then treated with tumor resection and use of an unc...

2017
Kiminori Yukata Issei Yamanaka Yuzuru Ueda Sho Nakai Hiroyoshi Ogasa Yosuke Oishi Jun-ichi Hamawaki

AIM To determine the location of medial tibial plateau stress fractures and its relationship with tibial plateau morphology using magnetic resonance imaging (MRI). METHODS A retrospective review of patients with a diagnosis of stress fracture of the medial tibial plateau was performed for a 5-year period. Fourteen patients [three female and 11 male, with an average age of 36.4 years (range, 1...

2017
Axel Gamulin Anne Lübbeke Patrick Belinga Pierre Hoffmeyer Thomas V Perneger Matthieu Zingg Gregory Cunningham

BACKGROUND The aim of the study was to evaluate the relation between demographic, injury-related, clinical and radiological factors of patients with tibial plateau fractures and the development of acute compartment syndrome. METHODS All consecutive adult patients with intra-articular tibial plateau fractures admitted in our urban academic medical centre between January 2005 and December 2009 ...

2010
Colin Yi-Loong Woon Merng-Koon Wong Tet-Sen Howe

The locking compression plate (LCP) is an angle-stable fixator intended for intracorporeal application. In selected cases, it can be applied externally in an extracorporeal location to function as a monolateral external fixator. We describe one patient with Schatzker V tibial plateau fracture and one patient with Gustillo IIIB open tibia shaft fracture treated initially with traditional externa...

Journal: :medical journal of islamic republic of iran 0
seyed abas behgoo iran university of medical sciences, tehran, iran.سازمان اصلی تایید شده: دانشگاه علوم پزشکی ایران (iran university of medical sciences) hajir gharati shafa yahyaian hospital, tehran, iran.سازمان اصلی تایید شده: دانشگاه علوم پزشکی ایران (iran university of medical sciences) mehdi ramezan shirazi shafa yahyaian hospital. baharestan sq., tehran, iran.سازمان اصلی تایید شده: دانشگاه علوم پزشکی ایران (iran university of medical sciences)

abstract   background: the tibial diaphyseal fractures are the most common type of long bone fractures encountered by most orthopedic surgeons. in accordance with descriptive indices of tibia fractures on the basis of their location in the bone, distal tibia fractures have the second incidence of all tibia fractures after the middle tibia fractures. the purpose of the study was to assess the co...

2016
Mauro Rodrigues dos Santos Junichiro Sado Roberto Medeiros de Sousa Osman Rodrigues Roriz

OBJECTIVE To evaluate the intra-observer reproducibility of Schatzker classification for tibial plateau fractures through smartphone applications. METHODS Radiographs were evaluated in two incidences (anteroposterior and profile) and CT slices (axial, sagittal and coronal) of 37 patients with tibial plateau fracture. Two evaluators, knee surgery experts, classified the cases by viewing the im...

Journal: :The Knee 2010
M Clarius D Haas P R Aldinger S Jaeger E Jakubowitz J B Seeger

Periprosthetic tibial plateau fractures (TPF) are rare but represent a serious complication of unicompartmental knee arthroplasty (UKA). As TPFs usually occur perioperatively, these can be associated with extended sagittal saw cuts during surgery. The aim of the study was to evaluate TPF as a function of extended sagittal saw cuts. The hypothesis was that extended sagittal saw cuts reduce the l...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید