نتایج جستجو برای: shunt active power filter

تعداد نتایج: 1024560  

Journal: :American Journal of Applied Sciences 2008

This paper presents a comparative analysis between two current control strategies, constant source power and generalized Fryze current, used in Active Power Filter (APF) applications having three different modulation methods. The Hysteresis Band (HB) and first-order Delta-Sigma Modulation (DSM) as well as the second-order DSM is applied. The power section of the active power filter is viewed as...

2011
B.SURESH KUMAR

This paper presents a fuzzy logic, PI controlled shunt active power filter used to compensate for harmonic distortion in three-phase four-wire systems. The shunt active filter employs a simple method for the calculation of the reference compensation current based on Fast Fourier Transform. The presented Shunt Active Power filter is able to operate in balanced, unbalanced and Variable load condi...

2014
Shiuly Mukherjee Nitin Saxena A K Sharma

This paper shows the method of improving the power quality using shunt active power filter. The proposed topic comprises of PI controller, filter hysteresis current control loop, dc link capacitor. The switching signal generation for filter is from hysteresis current controller techniques. With the all these element shunt active power filter reduce the total harmonic distortion. This paper repr...

2014
P. Shah

This paper describes a novel fuzzy logic controller for a three phase shunt active shunt filter for the power quality improvement. The Power Quality (PQ) problems in power distribution systems are not new but only recently the effects of these problems have gained public awareness. These non-linear loads are constructed by nonlinear devices in which the current is not proportional to the applie...

2008
Majid Nayeripour Taher Niknam

This paper proposes a new method of sliding mode base controller for shunt active power filter to compensate the harmonic currents of a load. In this controller there isn't any need to PI DC voltage controller to regulate the DC capacitor voltage of shunt active power filter. In this method, first the reference currents of shunt active power filter that should be tracked to reduce or eliminate ...

2008
A. GHASEMI S. S. MORTAZAVI R. KIANINEZHAD

This paper describes the application of a new fuzzy based control strategy to a three-phase shunt active power filter for harmonics minimization and reactive power compensation required by a variable non-linear load. To improve dynamic behaviour of shunt active power filter and make it robust under wide range of load variations, the value of load current is considered as an input of fuzzy contr...

2014
Sushil Karvekar Swapnil Patil

In this paper control of Goertzel Algorithm based shunt active power filter with sliding mode controller is considered. Shunt active power filter involves harmonics mitigation due to three phase non linear loads under balanced and unbalanced load conditions. The sliding mode controller is used to regulate voltage of the capacitor used in inverter. The sliding mode controller improves the dynami...

This paper demonstrates an enhancement of power quality in grid integrated systems with the help of the proposed control strategy for voltage source converter based active power filters. The Shunt Active Power filters (SAPF) are extensively utilized in modern grid integrated systems to diminish the power quality concerns associated with it. The SAPF is one of the various power filters, which ha...

Journal: :International Journal for Research in Applied Science and Engineering Technology 2019

نمودار تعداد نتایج جستجو در هر سال