نتایج جستجو برای: magat gel dosimeter

تعداد نتایج: 106939  

2013
N. Gopishankar S. Vivekanandhan G.K. Rath M.A. Laviraj S. Senthilkumaran S.S. Kale S. Thulkar R.K. Bisht V. Subramani

The purpose of this study was to validate the newly designed acrylic phantom for routine dosimetric purpose in radiotherapy. The phantom can be used to evaluate and compare the calculated dose and measured dose using film and gel dosimetric methods. In this study, a doughnut-shaped planning target volume (8.54 cm3) and inner organ at risk (0.353 cm3) were delineated for an IMRT test plan using ...

Journal: :Journal of physics 2022

Abstract The spatial distributions of neutrons and gamma rays in the epithermal mode Kyoto University Reactor were measured using a MAGAT-type polymer gel detector doped with LiCl at 6 Li concentrations 0, 10, 100 ppm. Reasonable for thermal obtained 0 100ppm.

Journal: :iranian journal of medical physics 0
hossein hasani m.sc. student in medical radiation engineering, science and research branch, islamic azad university, tehran, iran hasan nedaie assistant professor, radiotherapy and oncology dept., tehran university of medical sciences, cancer research center, center institute, tehran, iran mohammad hasan zahmatkesh associate professor, medical physics dept., novin medical radiation institute, tehran, iran mahmood allahverdi associate professor, medical physics dept., tehran university of medical sciences, tehran, iran saeid bagheri m.sc. of medical physics, novin medical radiation institute, shahid beheshti university, tehran, iran sajad mirzaie m.sc. student in medical radiation engineering, science and research branch, islamic azad university, tehran, iran

introduction: in radiotherapy, methods of treatment planning are becoming increasingly more complicated. this requires verification of the doses delivered to increasingly smaller and more precise regions. radiotherapy techniques are continuously employing smaller and smaller field sizes to deliver tighter radiation doses with higher therapeutic ratios, generating interest among researchers to p...

2014
S. M. Gafar

In this study the spectrophotometric response of the Toluidine Blue O (TBO)-gelatin gel dosimeter irradiated with gamma rays was characterized. Preparation of dyed-gelatin gel takes place in neutral medium; to give eventually gel dosimeter has a sharp absorbance peak at 635 nm that bleaches quantitatively upon irradiation and the colour change can be measured with UV-VIS spectrophotometer. The ...

Journal: :iranian journal of radiation research 0
d. shahbazi-gahrouei dr. d. shahbazi-gahrouei; dept. of medical physics, sharekord university of medical sciences, sharekord, iran.fax: +98-381-3334911

background: the compositions of ferrous sulphate, agarose and xylenol orange dye (fax) and ferrous sulphate, gelatin and xylenol orange dye (fgx) in solution of distilled water and sulphuric acid are two tissue-equivalent gel dosimeters. ionizing radiation causes oxidation of fe2+ ion to fe3+ ions which diffuse through the gel matrix and blur the image of absorbed dose over a period of hours af...

Journal: :Journal of Physics: Conference Series 2013

2017
Heather M Whitney Daniel F Gochberg C Waldenberg A Karlsson Hauer

The normoxic polymer gel dosimeter based on N-isopropyl acrylamide (NiPAM) is a promising full 3D-dosimeter with high spatial resolution and near tissue equivalency. NiPAM gel samples were irradiated to different doses using a linear accelerator. The absorbed dose was evaluated using MRI and statistical significance of the analysed data was calculated. The analysis was carried out using an in-h...

Journal: :iranian journal of medical physics 0
bakhtiar azadbakht instructor, medical radiation engineering dept, faculty of engineering, borujerd islamic azad university, borujerd, iran. *, mohammad hassan zahmatkesh associate professor, shahid beheshti university, evin, tehran, iran kamal haddad associate professor, nuclear engineering dept, faculty of engineering, shiraz university, shiraz, iran. saeid bagheri m.sc. in medical physics, shahid beheshti university, tehran, iran

introduction: the pagat polymer gel dosimeter melts at 30 ˚c and even at room temperature during the summer, so it needs to be kept in a cool place such as a refrigerator. to increase the stability of the pagat gel, different amounts of agarose were added to the pagat gel composition and the pagata gel was manufactured. material and methods: the pagata gel vials were irradiated using a co-60 ma...

Seyed Mohammad Mahdi Abtahi Vahid Anaraki

Introduction: Three physical conditions caused an external beam designated as a small field. The first is the loss of lateral charged particle equilibrium. The second is the effect of collimators on the primary photon source occlusion. The third condition is the size of the detector which is large compared to the field size. The most obvious perturbation effects in last condit...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید