The ultimate check of the actual dose delivered to a patient in radiotherapy can only be achieved by using in vivo dosimetry. This work reports a pilot study to test the applicability of a thermoluminescent dosimetric system for performing in vivo entrance dose measurements in external photon beam radiotherapy. The measurements demonstrated the value of thermoluminescent dosimetry as a treatmen...
Introduction Dosimetric accuracy is a major issue in the quality assurance (QA) program for treatment planning systems (TPS). An important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. In brachytherapy (BT) of gynecological (Gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...
Introduction: Electronic portal imaging devices (EPIDs) are extensively used for dosimetric information of pre-treatment field verification and in-vivo dosimetry for Intensity Modulated Radiotherapy (IMRT). In the present work, we have implemented the newly developed portal dosimetry software using independent dose prediction algorithm EPIDose and evaluated this new tool for the pretreatment IM...
introduction: the purpose of this work was to study the ability of mri normoxic polymer gel dosimetry for evaluating the dose distribution in hdr brachytherapy of esophagial cancer at imam reza brachytherapy center (mashhad, iran). materials and methods: initially, 2liters of normoxic gel (magic) was fabricated and then poured into 12 calibration test tubes and placed in a perspex walled phanto...
Introduction: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans both pretreatment and in-vivo. The aim of this study was to test a 2D EPID-based dosimetry algorithm for dose verification of some plans inside a homogenous and anthropomorphic phantom and in-vivo, as well. Materials and Methods: </strong...
PURPOSE Well-known defect of TG-43 based algorithms used in brachytherapy is a lack of information about interaction cross-sections, which are determined not only by electron density but also by atomic number. TG-186 recommendations with using of MBDCA (model-based dose calculation algorithm), accurate tissues segmentation, and the structure's elemental composition continue to create difficulti...
introduction: gafchromic ebt films are one of the self-developing and modern films commercially available for dosimetric verification of treatment planning systems (tpss). their high spatial resolution, low energy dependence and near-tissue equivalence make them suitable for verification of dose distributions in radiation therapy. this study was designed to evaluate the dosimetric parameters of...
Introduction: Tumor control and treatment quality depend on accuracy of delivered dose. Various methods have been studied for treatment dosimetry verification. Among these methods, the use of electronic portal imaging device (EPID) is highly considered. Many efforts are underway to improve the results of this context. Materials and Methods: In this study, ...
Lithium formate has shown to be a material with properties suitable for electron paramagnetic resonance (EPR) dosimetry, among them up to 7 times higher sensitivity compared to alanine, which is a well-established EPR detector material for dose determinations in radiotherapy. The aim of this thesis was to further investigate the properties of lithium formate and develop the dosimetry system tow...