نتایج جستجو برای: cobas amplicor monitor test

تعداد نتایج: 883872  

Journal: :Journal of clinical microbiology 1997
M Poljak K Seme S Koren

To evaluate the reliability and feasibility of the automated Roche COBAS AMPLICOR PCR system for routine detection of hepatitis C virus (HCV) RNA, a total of 405 serum samples previously tested by an in-house nested PCR and manual Roche AMPLICOR microwell plate HCV test were examined. Complete concordance was found between the results with the HCV COBAS AMPLICOR system and the previously determ...

Journal: :Journal of clinical microbiology 2005
Rafael M Gordillo Juan Gutiérrez Manuel Casal

The purpose of this study is to evaluate the usefulness of the new real-time PCR COBAS TaqMan 48 analyzer, comparing it to the existing COBAS AMPLICOR HBV MONITOR based on conventional PCR technology. The study used 104 samples from different patients. No differences were found in the sensitivity of the tests. There was an excellent correlation between the sample with a viral load within the dy...

Journal: :Journal of clinical microbiology 2011
Jeong Hyun Kim Young Jae Kim Chang-Seok Ki Ji-Youn Kim Nam Yong Lee

Nucleic acid-based amplification tests allow the rapid detection of Mycobacterium tuberculosis. Recently, a real-time PCR assay for M. tuberculosis complex, the Cobas TaqMan MTB test (Roche Diagnostics, Basel, Switzerland), was introduced. We performed a prospective study to evaluate the diagnostic performance of the Cobas TaqMan MTB test system. A total of 406 specimens collected from 247 pati...

Journal: :Journal of clinical microbiology 2004
Joseph D C Yao Marcel G H M Beld Lynette Lin Ean Oon Christopher H Sherlock Jeffrey Germer Sandra Menting Su Yun Se Thoe Linda Merrick Rainer Ziermann Johan Surtihadi H James Hnatyszyn

The VERSANT hepatitis B virus (HBV) 3.0 Assay (branched DNA [bDNA]) (referred to herein as VERSANT 3.0) was evaluated at four external sites for analytical sensitivity, specificity, reproducibility, linearity of quantification, and limits of detection. In addition, each of the test evaluation sites provided HBV DNA-positive clinical samples that were previously analyzed by one of three commerci...

Journal: :Journal of clinical microbiology 2013
Guido V Bloemberg Antje Voit Claudia Ritter Vanessa Deggim Erik C Böttger

The Roche Cobas Amplicor MTB assay, recently replaced by the Roche Cobas TaqMan MTB assay, was one of the first commercially available assays for detection of the Mycobacterium tuberculosis complex based on nucleic acid amplification. We reported previously on the limited specificity of the Cobas Amplicor MTB assay, in particular for positive samples with an optical density at 660 nm (OD660) of...

Journal: :Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology 2004
J Weiss H Wu B Farrenkopf T Schultz G Song S Shah J Siegel

BACKGROUND Diagnostic assays for the accurate quantitation of hepatitis B virus (HBV) DNA levels from patients undergoing antiviral therapy are useful for monitoring and tailoring therapy. Such assays should give accurate results with all HBV genotypes, including a seventh genotype of hepatitis B virus, genotype G, that has recently been identified in specimens from HBV-positive patients in the...

Journal: :Journal of virological methods 2000
A M Roque Afonso J Didier E Plouvier B Falissard M P Ferey M Bogard E Dussaix

The Amplicor HCV Monitor test for quantitative determination of serum or plasma hepatitis C virus (HCV) RNA was modified recently and introduced onto the Cobas Amplicor instrument to automate fully amplification, detection and calculation of results. This new version (v2.0) was evaluated in a routine diagnostic laboratory. The sensitivity and reproducibility were assessed on well-characterized ...

2014
Maximilian Muenchhoff Savathee Madurai Allison Jo Hempenstall Emily Adland Anna Carlqvist Angeline Moonsamy Manjeetha Jaggernath Busisiwe Mlotshwa Emma Siboto Thumbi Ndung'u Philip Jeremy Renshaw Goulder

Human immunodeficiency virus type 1 (HIV-1) genetic diversity poses a challenge to reliable viral load monitoring. Discrepancies between different testing platforms have been observed, especially for non-clade-B virus. Therefore we compare, in antiretroviral therapy (ART)-naïve South African subjects predominantly infected with HIV-1 clade-C, three commercially available assays: the COBAS Ampli...

2004
Heli Piiparinen Irmeli Lautenschlager Hannu Jalanko Cathrien Bruggeman

List of original publications 7 Abbreviations 8 Summary 9 Review of the literature 10 1. Human cytomegalovirus 10 1.1. Virus structure and genome organization 10 1.2. Virus replication 10 1.3. Epidemiology and transmission 11 1.4. Pathogenesis 12 2. Human cytomegalovirus infections in organ transplant patients 14 2.1. Clinical manifestations 14 2.2. Prevention and treatment of HCMV disease 15 2...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید