نتایج جستجو برای: artisan iol

تعداد نتایج: 2687  

Journal: :Journal of refractive surgery 2006
Miltiadis Aspiotis Ioannis Asproudis Maria Stefaniotou Spiridon Gorezis Konstantinos Psilas

PURPOSE To assess implantation of an Artisan aphakic intraocular lens (IOL) in cases with subluxated lenses due to Marfan syndrome. METHODS Retrospective study of a small case series comprised of seven eyes (two children and three adults) with subluxated lenses due to Marfan syndrome that underwent lens extraction and Artisan aphakic IOL implantation. Best spectacle-corrected visual acuity an...

Journal: :Journal of cataract and refractive surgery 2004
Majid Moshirfar Charles A Barsam Jared W Parker

We report 2 cases in which an Artisan phakic intraocular lens (IOL) (Ophtec) was used to successfully treat high myopia after penetrating keratoplasty (PKP). The first case was a 43-year-old man who had a manifest refraction of -13.75 +3.00 x 50 with a best corrected visual acuity (BCVA) of 20/40(-2) after PKP in the left eye. Approximately 9 months after implantation of the Artisan IOL, the ma...

Journal: :بینا 0
پرویز ملکی فر p malekifar ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranدانشگاه علوم پزشکی شهید بهشتی- تهران- ایران حسین محمدربیع h mohammad rabie ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranدانشگاه علوم پزشکی شهید بهشتی- تهران- ایران فاطمه جوادی f javadi ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranدانشگاه علوم پزشکی شهید بهشتی- تهران- ایران حامد اسفندیاری h esfandiari ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranدانشگاه علوم پزشکی شهید بهشتی- تهران- ایران

purpose: to report clinical outcomes of crystalline lens extraction and iris claw artisan intraocular lens (iol) implantation in patients with lens subluxation secondary to marfan syndrome.  methods: this retrospective study enrolled 14 eyes of 12 marfan patients with lens subluxation who underwent crystalline lens removal and artisan iol implantation. pre- and post-operative data, including pa...

Journal: :Cornea 2008
Damian B Lake Chad K Rostron

PROBLEM Effective tamponade of a Descemet-stripping endothelial keratoplasty graft with a gas bubble requires that there is no route for the bubble to escape into the posterior chamber. SOLUTION Exchange the angle-supported anterior-chamber intraocular lens (IOL) for an iris-enclaved Artisan IOL and position the IOL haptics over the peripheral iridectomy to occlude it to the extent that no ga...

Journal: :Journal of cataract and refractive surgery 2005
José L Güell Fortino Velasco Francois Malecaze Mercedes Vázquez Oscar Gris Felicidad Manero

PURPOSE To evaluate efficacy, predictability and safety of Artisan-Verysise intraocular lens (IOL) secondary implantation for aphakia correction. SETTING Instituto de Microcirugía Ocular, and Autonoma University of Barcelona, Barcelona, Spain. METHODS Uncorrected visual acuity, best spectacle-corrected visual acuity (BSCVA), manifest refraction, endothelial cell count, and clinical complica...

Journal: :Journal of cataract and refractive surgery 2007
Sung Jin Lee

Traumatic aniridia and aphakia occurred in the left eye of a 22-year-old man who had had Artisan (Ophtec) phakic intraocular lens (IOL) implantation. Aniridia was probably the result of the relatively large wound used to implant the nonfoldable IOL. Although the eye had severe traumatic damage, vision was recoverable through a 2-stage procedure of vitrectomy and subsequent scleral suture fixati...

2006
Marije L. Sminia Liesbeth J. J. M. Prick Nitza Gortzak-Moorstein

Purpose: To retrospectively estimate the long-term corneal endothelial cell loss in children after perforating corneal trauma and implantation of an iris-fixated anterior-chamber intraocular lens (IOL), either the Artisan aphakia lens or the Artificial Iris Implant, and to compare this corneal endothelial cell loss to that in children who received an Artisan aphakia lens to correct aphakia afte...

2014

JULY 2014 CATARACT & REFRACTIVE SURGERY TODAY 55 M any techniques have been described for correcting aphakia with inadequate capsular support. The most common IOLs that are used include anterior chamber, posterior chamber, iris-fixated, and scleral-sutured IOLs; however, there is no current agreement on the ideal technique or technology. The Artisan aphakia lens (Ophtec; marketed as the Verisys...

Journal: :Journal of cataract and refractive surgery 2003
Ruchi Saxena Helena M van Minderhout Gregorius P M Luyten

We report a child who had implantation of an iris-fixated Artisan phakic intraocular lens (IOL) to correct high unilateral myopia to support the therapy of anisometropic amblyopia. After IOL implantation, the patient continued occlusion therapy to further treat the amblyopic eye. One year postoperatively, the best corrected visual acuity in the amblyopic eye was 1.00 and binocular stereovision ...

Journal: :بینا 0
مهدی خانلری m khanlari vanak eye surgery center, tehran, iranتقاطع آفریقا و میرداماد- مرکز جراحی آلفا علی فیض­زاده a feizzadeh tehran university of medical sciencesتقاطع آفریقا و میرداماد- مرکز جراحی آلفا

purpose: to assess hoffer correction factor in measurement of axial length (al) in eyes with phakic iol implants. methods: in this descriptive historical cohort study, axial length was measured by ultrasound (us) and iol master in both phakic and pseudophakic modes in 24 eyes of 14 patients with artisan intraocular lenses (iols) implanted for refractive purposes, hoffer’s suggested formula for ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید