نتایج جستجو برای: ctdi

تعداد نتایج: 191  

Journal: :Physics in medicine and biology 2017
R Kramer V F Cassola M E A Andrade M W C de Araújo D J Brenner H J Khoury

The purpose of bowtie filters in CT scanners is to homogenize the x-ray intensity measured by the detectors in order to improve the image quality and at the same time to reduce the dose to the patient because of the preferential filtering near the periphery of the fan beam. For CT dosimetry, especially for Monte Carlo calculations of organ and tissue absorbed doses to patients, it is important ...

2014
M. Goyal T. Beppu

SUMMARY: Technologic advances in CT have generated a dramatic increase in the number of CT studies, with a resultant increase in the radiation dose related to CT scanning. Such increase in radiation dose is becoming a concern for the radiology community, especially with increasing public awareness of the dose burden related to examinations. To cope with the increase in CT-related radiation expo...

2011
Thomas Fearon Huchen Xie Jason Y. Cheng Holly Ning Ying Zhuge Robert W. Miller

Current estimation of radiation dose from computed tomography (CT) scans on patients has relied on the measurement of Computed Tomography Dose Index (CTDI) in standard cylindrical phantoms, and calculations based on mathematical representations of "standard man". Radiation dose to both adult and pediatric patients from a CT scan has been a concern, as noted in recent reports. The purpose of thi...

Journal: :iranian journal of radiation research 0
f. bouzarjomehri department of medical physics, shahid sadoghi university of medical sciences, yazd, iran m. h. zare department of medical physics, isfahan university of medical sciences, isfahan, iran d. shahbazi department of medical physics, isfahan university of medical sciences, isfahan, iran

abstract   background: while the benefits of computed tomography (ct) are well known in accurate diagnosis, those benefits are not risk free. ct is a device with higher patient dose in comparison with other conventional radiological procedures. is the reduction of exposures by requiring optimization of ct procedures [a principle concern in radiological protection]? in this study, the radiation ...

D. Shahbazi, F. Bouzarjomehri, M. H. Zare,

  ABSTRACT   Background: While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk free. CT is a device with higher patient dose in comparison with other conventional radiological procedures. Is the reduction of exposures by requiring optimization of CT procedures [a principle concern in radiological protection]? In this study, the radiatio...

باختر, مرضیه, رضائیان, محسن, رفیعی, ریحانه, زارع بیدکی, محمد,

Background and Objective: Critical thinking is the type of thinking that follows evidence in order to achieve a reliable result. The present study aimed to assess the critical thinking among faculty members of Rafsanjan University of Medical Sciences in 2013 on the basis of age, gender, type of employment, academic rank, administrative activities, teaching experiences, number of courses, and ty...

2014
Agostino Chiaravalloti Roberta Danieli Cristiana Ragano Caracciolo Laura Travascio Maria Cantonetti Andrea Gallamini Manlio Guazzaroni Antonio Orlacchio Giovanni Simonetti Orazio Schillaci Julhash U Kazi

The objective of this study was to compare the diagnostic accuracy of positron emission tomography/low-dose computed tomography (PET/ldCT) versus the same technique implemented by contrast-enhanced computed tomography (ceCT) in staging Hodgkin’s disease (HD). Forty patients (18 men and 22 women, mean age 30 9.6) with biopsy-proven HD underwent a PET/ldCT study for initial staging including an u...

2013
K. Juluru P. C. Sanelli

BACKGROUNDAND PURPOSE: There is a desire within many institutions to reduce the radiation dose in CTP examinations. The purpose of this study was to simulate dose reduction through the addition of noise in brain CT perfusion examinations and to determine the subsequent effects on quality and quantitative interpretation. MATERIALS ANDMETHODS: A total of 22 consecutive reference CTP scans were id...

2014
Ganesh Saiprasad James Filliben Adele Peskin Eliot Siegel Joseph Chen Christopher Trimble Zhitong Yang Olav Christianson Ehsan Samei Elizabeth Krupinski Alden Dima

Purpose: To compare image resolution using Iterative Reconstruction (IR) with the resolution using Filtered Back Projection (FBP), for low-contrast objects in phantom images across vendors and exposure levels. Materials and Methods: Randomized repeat scans of the Gammex 464 American College of Radiology (ACR) CT Accreditation Phantom (Module 2, Low-contrast) were performed for multiple radiatio...

Journal: :Medical physics 2012
J Xu D D Reh J P Carey M Mahesh J H Siewerdsen

PURPOSE As cone-beam CT (CBCT) systems dedicated to various imaging specialties proliferate, technical assessment grounded in imaging physics is important to ensuring that image quality and radiation dose are quantified, understood, and justified. This paper involves technical assessment of a new CBCT scanner (CS 9300, Carestream Health, Rochester, NY) dedicated to imaging of the ear and sinuse...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید