T Inoue S Sugimoto K Fukata C Kurokawa S Ozawa K Sasai

PURPOSE To evaluate the energy dependence of Gafchromic EBT3 film for establishing a quality assurance method of bolus electron conformal radiotherapy. METHODS We irradiated electron beam to EBT3 films, which were set in the water tank. The linear accelerator used was Varian Clinac 21EX. The energy of electron beams were 9 and 12 MeV. The irradiated field size was 10×10 cm2 and the source to ...

1998
T. L. Houck D. E. Anderson S. Eylon E. Henestroza S. M. Lidia D. L. Vanecek G. A. Westenskow S. S. Yu

We are constructing a 1.2 kA, 1 MeV, electron induction injector as part of the RTA program, a collaborative effort between LLNL and LBNL to develop relativistic klystrons for Two-Beam Accelerator applications. The RTA injector will also be used in the development of a high-gradient, low-emittance, electron source and beam diagnostics for the second axis of the Dual Axis Radiographic Hydrodynam...

2006
M. C. Thompson H. Badakov J. B. Rosenzweig G. Travish R. Fliller G. M. Kazakevich P. Piot J. Santucci J. Li R. Tikhoplav

Focusing of a 15 MeV, 16 nC electron bunch by a gaussian underdense plasma lens operated just beyond the threshold of the underdense condition has been demonstrated. The strong 1.9 cm focal length plasma lens focused both transverse directions simultaneously and reduced the minimum area of the beam spot by a factor of 23. Analysis of the beam envelope evolution observed near the beam waist show...

Journal: :Physical review letters 2002
V M Malkin N J Fisch

The energy deposition of a relativistic electron beam in a plasma can be managed through turning on or off fast beam-plasma instabilities in desirable regions. This management may enable new ways of realizing the fast-igniter scenario of inertial fusion. Collisional effects alone can decelerate electrons of at most a few MeV within the core of an inertial-fusion target. Beam-excited Langmuir tu...

1999
S. Henderson

The beam energy at the Cornell Electron Storage Ring must be maintained within 1 MeV of the (4S) resonance peak. The beam energy is determined on a run-by-run basis by calculation based upon machine parameters. As a test of the energy calculation we have explored a technique for determining the relative CESR beam energy using synchrotron radiation. We describe the technique and present a status...

2009
F. M. Bieniosek P. Forck P. A. Ni D.H.H. Hoffmann

Non-intercepting Beam Induced Fluorescence (BIF) monitors measure transversal beam profiles by observation of fluorescence light originating from excited residual gas molecules. Thus they are an alternative to conventional intercepting devices. Single photon counting is performed using an image intensified digital CCD camera. We investigated the BIF process in the energy range of 7.7 keV/u to 7...

2000
G. Guethlein

The next generation of radiographic machines based on induction accelerators is expected to generate multiple, small diameter x-ray spots of high intensity. Experiments to study the interaction of the electron beam with plasmas generated at the x-ray converter and at beamline septa are being performed at the Lawrence Livermore National Laboratory (LLNL) using the 6-MeV, 2-kA Experimental Test A...

1998
V. L. Auslender M. V. Korobeynikov V. I. Serbin

The installation for sterilization of disposal medical goods based on the ILU electron accelerators Are described. The industrial installation is running where the syringes are sterilized in consumer packs directly by the electron beam having energy of 2.6 MeV. The different irradiation technologies for immobilization of enzymes, production of medical preparations and gels for medical and techn...

Journal: :Physics in medicine and biology 2008
Eric E Klein Milos Vicic Chang-Ming Ma Daniel A Low Robert E Drzymala

Treating shallow tumors with a homogeneous dose while simultaneously minimizing the dose to distal critical organs remains a challenge in radiotherapy. One promising approach is modulated electron radiotherapy (MERT). Due to the scattering properties of electron beams, the commercially provided secondary and tertiary photon collimation systems are not conducive for electron beam delivery when s...