نتایج جستجو برای: spot diameter

تعداد نتایج: 147364  

Journal: :Applied optics 2013
Won-Gyum Kim Nam-Won Moon Manoj Kumar Singh Hwang-Kyeom Kim Yong-Hoon Kim

Quasi-optical imaging systems require low blurring effect and large depth of focus (DOF) to get an acceptable sharpness of the image. To reduce aberration-limited blurring, the aspheric convex plano lenses with an aperture diameter of 350 mm are designed in W-band. We analyzed theoretically and experimentally the millimeter-wave band lens characteristics, such as beam spot size, spatial resolut...

Journal: :The Review of scientific instruments 2008
M Otendal T Tuohimaa U Vogt H M Hertz

We demonstrate a high-brightness compact 9 keV electron-impact microfocus x-ray source based on a liquid-gallium-jet anode. A approximately 30 W, 50 kV electron gun is focused onto the approximately 20 ms, 30 mum diameter liquid-gallium-jet anode to produce an approximately 10 microm full width at half maximum x-ray spot. The peak spectral brightness is >2 x 10(10) photons(s mm(2) mrad(2)x0.1% ...

Journal: :Journal of biomedical optics 2010
Woonggyu Jung Wladimir Benalcazar Adeel Ahmad Utkarsh Sharma Haohua Tu Stephen A Boppart

We report the numerical analysis of gradient index (GRIN) lens-based optical coherence tomography imaging probes to derive optimal design parameters. Long and short working distance probes with a small focal spot are considered. In each model, the working distance and beam waist are characterized and compared for different values of length and refractive index of the probe components. We also e...

Journal: :Micromachines 2016
Kevin O'Brien Ming Zhao David Nolte

Spinning-disc interferometry (SDI) is a high-speed laser scanning approach to surface metrology that uses common-path interferometry to measure protein spots on a BioCD disk. The measurement sensitivity depends on the scanning pitch and on the time-base. Based on high-resolution laser scanning images of printed antibody spots, we quantify the protein sensitivity as a function of the scan parame...

Journal: :Optics letters 1999
B R Benware A Ozols J J Rocca I A Artioukov V V Kondratenko A V Vinogradov

We focused the beam of a high-repetition-rate capillary-discharge tabletop laser operating at a wavelength of 46.9 nm, using a spherical Si/Sc multilayer mirror. The energy densities significantly exceeded the thresholds for the ablation of metals. Single-shot laser ablation patterns were used in combination with ray-tracing computations to characterize the focused beam. The radiation intensity...

Journal: :The journal of physical chemistry. B 2013
Anwar Usman Wei-Yi Chiang Takayuki Uwada Hiroshi Masuhara

We experimentally demonstrate reordering throughout the inside of an individual bipolar nematic liquid-crystalline microdroplet optically trapped by a highly focused laser beam, when the laser powers are above a definite threshold. The threshold depends on the droplet size and laser polarization. A physical interpretation of the results is presented by considering the nonlocal orientations of t...

Journal: :Medicina 2015
José Pablo Chiappe Pablo Nahum Javier F Casiraghi Rafael Iribarren

This study assessed optic disc size and cupping, using a commercially available ophthalmoscope, in order to show norms of these values for clinical practice. Subjects were office-workers referred from their respective workplaces for a routine medical examination, which included eye examination. The optic disc size was classified as small, medium or large, for having a diameter < 1.0, 1.0-1.5, o...

2013
Chie Toramatsu Norio Katoh Shinichi Shimizu Hideaki Nihongi Taeko Matsuura Seishin Takao Naoki Miyamoto Ryusuke Suzuki Kenneth Sutherland Rumiko Kinoshita Rikiya Onimaru Masayori Ishikawa Kikuo Umegaki Hiroki Shirato

BACKGROUND We performed a dosimetric comparison of spot-scanning proton therapy (SSPT) and intensity-modulated radiation therapy (IMRT) for hepatocellular carcinoma (HCC) to investigate the impact of tumor size on the risk of radiation induced liver disease (RILD). METHODS A number of alternative plans were generated for 10 patients with HCC. The gross tumor volumes (GTV) varied from 20.1 to ...

Journal: :Optics letters 1998
B A Richman S E Bisson R Trebino E Sidick A Jacobson

Using a lossless dispersive apparatus consisting of six prisms, optimized to match a second-harmonic crystal phase-matching angle versus wavelength to second order, we efficiently doubled tunable fundamental light near 660 nm over a range of 80 nm, using a 4-mm-long type I beta -barium borate crystal without tuning the crystal angle. Another set of six prisms after the crystal realigned the pro...

2017
P. W. M. Blom J. J. L. Horikx P. J. H. Bloemen C. A. Verschuren H. W. van Kesteren H. Awano N. Ohta

In a magnetic amplifying magnetooptical system (MAMMOS) disk, the copying process of a magnetic domain from the recording layer into the readout layer is investigated by using a laser spot diameter of 0.66 m. Interference between neighboring bits occurs when the spatial resolution of the copy process is larger than half the domain size. It is observed that a reduction of the readout power from ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید