Journal: :Nanoscale 2017
D S Schneider A Bablich M C Lemme

We report on the integration of large area CVD grown single- and bilayer graphene transparent conductive electrodes (TCEs) on amorphous silicon multispectral photodetectors. The broadband transmission of graphene results in 440% enhancement of the detectors' spectral response in the ultraviolet (UV) region at λ = 320 nm compared to reference devices with conventional aluminum doped zinc oxide (...

Journal: :Journal of the American Society for Mass Spectrometry 2015
Andrew N Krutchinsky Júlio C Padovan Herbert Cohen Brian T Chait

We demonstrate that the efficiency of ion transmission from atmosphere to vacuum through stainless steel electrodes that contain slowly divergent conical duct (ConDuct) channels can be close to 100%. Here, we explore the properties of 2.5-cm-long electrodes with angles of divergence of 0°, 1°, 2°, 3°, 5°, 8°, 13°, and 21°, respectively. The ion transmission efficiency was observed to jump from ...

Journal: :The Review of scientific instruments 2007
Pierre Thibault Pantxo Diribarne Thierry Fournier Sylvain Perraud Laurent Puech P-Etienne Wolf Bernard Rousset Roser Vallcorba

This article evaluates the potential of capacitive measurements using flexible electrodes to access various physical quantities. These electrodes are made of a thin metallic film, typical thickness 0.2 microm, evaporated on a plastic substrate. Their large flexibility enables them to be mounted in complex geometries such as curved surfaces. In the configuration of planar condensers, using a ver...

Journal: :IEEE Trans. Instrumentation and Measurement 2001
Edmond Cretu Luís Alexandre Rocha Reinoud F. Wolffenbuttel

The pull-in voltage of a single-side anchored freestanding beam, under lateral deflection, has been investigated for application as a dc voltage reference. Two sets of electrodes, alongside the tip, are used for parallel-plate type of electrostatic actuation of the 200 m long beam in the plane of the wafer. Another set of buried electrodes is aligned with the plate electrode at the free-standin...

Journal: :Circulation research 1964
M LAVALLEE

• Caldwell* was the first to measure directly the pH of large cells (crab muscle fibres) with a glass electrode. Kostyuk and Sorokina reduced considerably the dimensions of the glass electrode and measured directly the intracellular pH of sartorius muscle (frog). Finally, Carter first measured the intracellular pH of a mammalian cell (rat voluntary muscle) by means of a double-barreled microele...

Journal: :American journal of physiology. Cell physiology 2013
Jonathan M Berman Mouhamed S Awayda

Electrophysiological techniques make use of Ag/AgCl electrodes that are in direct contact with cells or bath. In the bath, electrodes are exposed to numerous experimental conditions and chemical reagents that can modify electrode voltage. We examined voltage offsets created in Ag/AgCl electrodes by exposure to redox reagents used in electrophysiological studies. Voltage offsets were measured in...

2007
W. E. MoRF W. SIMoN

The ion selectivity exhibited by different types of membrane electrodes is rationalized by a theoretical treatment of the membrane potential. An equation, which is admirably suited for the interpolation of e.m.f.-values, is derived for the electrode response of membrane electrodes of the electrically neutral ligand type (antibiotics, model compounds) to mixed solutions of monovalent and divalen...

2009
Samuel P. Kounaves Michael H. Hecht Steven J. West John-Michael Morookian Suzanne M. M. Young Richard Quinn Paula Grunthaner Xiaowen Wen Mark Weilert Casey A. Cable Anita Fisher Kalina Gospodinova Jason Kapit Shannon Stroble Po-Chang Hsu Benton C. Clark Douglas W. Ming Peter H. Smith

[1] To analyze and interpret the chemical record, the 2007 Phoenix Mars Lander includes four wet chemistry cells. These Wet Chemistry Laboratories (WCLs), part of the Microscopy, Electrochemistry, and Conductivity Analyzer (MECA) package, each consist of a lower ‘‘beaker’’ containing sensors designed to analyze the chemical properties of the regolith and an upper ‘‘actuator assembly’’ for addin...

Journal: :Gut 1972
E Q Archampong C J Edmonds

Skin electrodes are the most convenient reference electrodes for clinical measurements of electrical potential differences (pd) across the epithelium of the alimentary tract but the presence of an electrical charge on normal skin introduces an error. In the present study, by comparison with results obtained using subcutaneous and intravenous electrodes, it was shown that an intradermal injectio...

Journal: :Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology 2006
Sharon M B Joines Carolyn M Sommerich Gary A Mirka James R Wilson Samuel D Moon

Musculoskeletal neck discomfort is prevalent in many occupations and has been the focus of much research employing surface electromyography (sEMG). Significant differences in experimental methods among researchers make comparisons across studies difficult. The goal of the current research was to use empirical methods to answer specific methodological questions concerning use of sEMG in evaluati...

نمودار تعداد نتایج جستجو در هر سال