نتایج جستجو برای: gamma knife monte carlo code sdd
تعداد نتایج: 360235 فیلتر نتایج به سال:
Because the experimental efficiency calibration is limited to several measurement geometries and cannot be applied directly to all measurement configurations, the efficiency transfer method for the efficiency computation was applied using ETNA software. An approach using efficiencies measured with point sources combined with theoretical procedures was applied for obtaining the peak efficiency ε...
The Monte Carlo method was used to calculate the photon detection efficiency and energy resolution curves for a 1.500 100 NaI(Tl) scintillator detector (crystal þ housing þ photomultiplier tube material equivalent) exposed to gamma rays in the energy range from 20 keV to 662 keV. This work aims to design a precise computational model, based in Monte Carlo simulation, which can be used in practi...
Intraoperative electron radiotherapy is one of the radiotherapy methods that delivers a high single fraction of radiation dose to the patient in one session during the surgery. Beam shaper applicator is one of the applicators that is recently employed with this radiotherapy method. This applicator has a considerable application in treatment of large tumors. In this study, the dosimetric charact...
Introduction: With the extensive application of radiation sources and radioactive materials in various fields, the study of attenuation and absorption of X-rays and gamma-rays in several materials has become an essential and interesting field of research. Glass materials are possible alternatives of concretes for radiation-shielding materials. Materials and Methods:...
Stochastic isogeometric analysis on arbitrary multipatch domains by spline dimensional decomposition
This paper presents a new stochastic method by integrating spline dimensional decomposition (SDD) of high-dimensional random function and isogeometric analysis (IGA) on arbitrary multipatch geometries to solve boundary-value problems from linear elasticity . The method, referred as SDD-mIGA, involves (1) analysis-suitable T-splines with significant approximating power for geometrical modeling, ...
Introduction: The CT machine utilizes a bowtie filter to shape the X-ray beam and remove lower energy photons. Configuration of this bowtie filter is complex and its geometry is often not available in detail. It causes the CT dose index (CTDI) be with the different values in measurement versus Monte Carlo simulation studies and other analytical calculations. It is important esp...
*Corresponding author: Dr. Tayyeb Allahverdi Pourfallah, Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran. Fax: +98 21 88973653 E-mail: [email protected] Background: Polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. MRI Polymer gel dosimeters are tissue equi...
exposure buildup factors have been calculated by monte carlo method for point isotropic gamma ray sources, penetrating a two-layer spherical shield of water surrounded by lead, and the effect of bremsstrahlung radiation on buildup factors has, in particular, been investigated, the results of which are in good agreement with previous works. the buildup factors were then calculated for various co...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید